5.2.2 Heating sensor (NTC-sensor)

Description
The heating sensor is placed next to the fan motor on the back of the machine.
The heating sensor measures the temperature in the outlet air and the signal is returned to the PCB.
The PCB turns the heating unit off when the outlet air thermistor indicates that the required temperature has been
reached.
Replacement of heating sensor (NTC-sensor)
Disconnect the power to the machine.
Demount the lower rear panel.
Disconnect the heating sensor and remove it. Connect the new heating sensor and put it in position. Make sure the
sensor gets all the way in.
fig.W00250A
Remount the lower rear panel.

5.3 Vacuum switch

Function
The vacuum switch is placed next to the heating module on the back of the machine.
The vacuum switch ensures the necessary airflow in the machine.