3.6.5
Repeat procedures 3.6.2 through 3.6.4 for the other screen modes.
(Completion of the red adjustment)
3.7 Coarse Adjustment and Fine Adjust-
ment of the Blue
Make coarse and fine-adjustments of the blue in the same manner
as with the red, described in 3.5 and 3.6.
3.8 Confirmation of Adjustment
After the green, red, and blue adjustments are finished, check
convergence errors with the patterns for all three colors on the
monitor.
Check the patterns in all SCREEN modes, and if any error in
convergence is recognized, readjust convergence in MANUAL
CONVER. mode.
Note: Be sure NOT to change the green pattern during readjustment.
IMPORTANT!
(1) When all the adjustments are completed, or when adjustment
should be temporarily interrupted, adjustment data must be
written to the EEPROM, in the following manner:
7

White Balance Adjustment

7
Contrast Adjustment
-1
Start
1st FAC
TV CBL
VCR
DVD
TV
/SAT
/LD
/DTV
TV
INPUT
1
2
3
4
SPLIT
SEARCH
SELECT
SCREEN
SUB CH
MODE
ANT
FREEZE
DISPLAY
1
2
3
4
5
6
7
8
9
CH
0
ENTER
¢
CH
RETURN
CH
VOL
MUTING
4
3
EDIT/
TV/SAT/DVD
DTV/DVD TOP
LEARN
MENU
MENU
SOURCE
DTV/SAT
5
POWER
GUIDE
2
SET/
3
ENTER
DTV/(SAT)
8
INFO
FAVORITE CH
VCR REC
1
7
3
¡
RECEIVER
INPUT
VOL
VOL
Î
HDTV PROJECTION MONITOR
"Normal video signal"
After the STD adjustment is complete, adjust the COMP 15K, COMP 31K, 33K RGB, COLOR TEMP FILM or STD and COLOR
TEMP B&W for STD.
"Color Bar"
Adjust the screen to optimum condition.
ADJUSTMENT OFFSET
CONTR
PRO-720HD, PRO-620HD, PRO-520HD
When all the adjustments are completed, or to interrupt
adjustment, press the MENU key to quit Convergence
Adjustment mode. The display will be unstable for several
seconds, but this is because the data are being written to the
EEPROM. Wait without doing anything until the display
becomes stable, which means writing of data to the EEPROM is
finished.
If the power of the TV is turned off (standby) during Convergence
Adjustment mode (coarse and fine-adjustments), turn on the TV,
enter FACTORY mode, and enter Convergence Adjustment
mode by pressing the SET/ENTER key. Then press the MENU
key. The data will be written to the EEPROM as described above.
(2) Do NOT turn off the main power during or after convergence
adjustment.
If you do so, the adjusted data may be lost. If the data are lost,
you must make all the adjustments again.
(3) When the CENTER POINT (test cross) or MULTI-POINT (user
convergence) adjustments have been made by a user, and if the
unit enters FACTORY Convergence Adjustment mode (with the
DOT and SET/ENTER keys), the user's adjustment data will be
all cleared and returned to the factory-preset values.
Be sure NOT to enter this Convergence Adjustment mode except
when a repair related to convergence or a repair that requires
convergence adjustment later, is needed.
If you inadvertently enter Convergence Adjustment mode,
readjust the convergence.
At the TP-BK of the B CRT DRIVE Assy, check that the signal
is shaped as shown below.
Shapely waveform
Shapeless waveform
Saturated