Below is a list of possible error codes and suggested remedies.
ERROR CODE
01
11
12
13
20
21
22
23
30
31
32
40
41
42
43
44
45
50
51
52
53
DESCRIPTION
Sensor 0 low output
Sensor 1 low output
Sensor 2 low output
Sensor 3 low output
Sensor 0 high output
Sensor 1 high output
Sensor 2 high output
Sensor 3 high output
V center or skew
loop overflow
H center or skew
loop overflow
H linearity or size
loop overflow
V center registration
data overflow
H center registration
data overflow
V SKEW registration
data overflow
H SKEW registration
data overflow
H linearity registration
data overflow
H size registration
data overflow
V center registration
data overflow
H center registration
data overflow
V skew registration
data overflow
H skew registration
data overflow
Table 28-1
REMEDY
Check if flags are hitting sensor properly. Adjust
VUP if necessary. Could be a sensor problem.
Check if flags are hitting sensor properly. Adjust
HLE if necessary. Could be a sensor problem.
Check if flags are hitting sensor properly. Adjust
HRIV if necessary. Could be a sensor problem.
Check if flags are hitting sensor properly. Adjust
VLOW if necessary. Could be a sensor problem.
Faulty sensor or associated circuit
Faulty sensor or associated circuit
Faulty sensor or associated circuit
Faulty sensor or associated circuit
Check mechanical V skew, V center and/or
VMID data.
Check mechanical H skew, H center and/or
HMID data.
Check H size, HLE and HRIV data
Check VMID data. Confirm V center data is
not near 511 for all modes
Check HMID data. Confirm H center data is
not near 511 for all modes.
Check VMID data. Confirm V skew data is
Not near 511 for all modes.
Check HMID data. Confirm H skew data is
not near 511 for all modes.
Check HLE and HRIV data. Confirm H center
data is not dear 511 for all modes.
Check HLE and HRIV data. Confirm H center
data is not near 511 for all modes.
Check VMID data. Confirm V center data is
not near –512 for all modes.
Check HMID data. Confirm H center data is
not near –512 for all modes.
Check VMID data. Confirm V skew data is
not near –512 for all modes.
Check HMID data. Confirm H skew data is
not near –512 for all modes.