Available languages

Quick Links

http://waterheatertimer.org/Countdown-timer-horsepower-ratings.html
English

Countdown Timer

MA-T51
120 V
60 Hz 5 A Lighting* or 3 A Fan
MA-T530G
120 V
60 Hz 5 A Lighting* or 3 A Fan
*See Timer Capacity Chart.
Important Notes
Please read before installing.
1. CAUTION! To avoid overheating and possible damage to other
equipment, do not use to control receptacles, fluorescent lighting
fixtures, motor-operated or transformer-supplied appliances.
2. Install in accordance with all national and local electrical codes.
3. Do not use for loads switched from 2 or more locations.
4. DO NOT use Maestro
controls for compact fluorescent lamps.
®
5. When no "grounding means" exist within the wallbox then the NEC
2008, Article 404-9 allows a control without a grounding connection to
be installed as a replacement, as long as a plastic, noncombustible
wallplate is used. For this type of installation, cap or remove the green
ground wire on the control and use an appropriate wallplate such as
Lutron's Claro
or Satin Colors
series wallplates.
®
®
6. Protect Timer from dust, dirt, and paint when spackling or painting.
7. Do not use where total load current is less than 0.3 A or greater than
5 A (see Timer Capacity Chart for details).
8. Operate between 0 °C (32 °F) and 40 °C (104 °F).
9. Timer may feel warm to the touch during normal operation.
10. Recommended wallbox depth is 2 ½ in (64 mm) minimum.
11. For safety reasons, do not use to control fixtures that are the only
source of illumination for an area.
12. When controlling a combined fan and light load, the total load may not
exceed 3 A.
13. Clean Timer with a soft damp cloth only . Do not use any chemical cleaners.
Multigang Installations
When installing more than one control in the same wallbox, it may be
necessary to remove all inner side sections prior to wiring (see below). Using
pliers, bend side sections up and down until they break off. Repeat for each
side section to be removed. Removal of Timer side sections reduces maximum
load capacity. Refer to chart below for maximum Timer capacity.
Do Not Remove
Outside Sections
Breaking Side Sections
Each Control Has
Middle Control Has Two
Inside Section
Side Sections Removed
Removed
Timer Capacity Chart
Maximum Load
No Sides
1 Side
2 Sides
Load Type
Removed
Removed
Removed
Halogen/Incandescent
600 W
500 W
400 W
120 V~
Magnetic Low Voltage**
600 VA / 450 W
500 VA / 400 W
400 VA / 300 W
General Purpose Fan
3 A
3 A
3 A
**Note: The maximum lamp wattage is determined by the efficiency of the transformer, with 70–85% as
typical. For actual transformer efficiency, contact either the fixture or transformer manufacturer. The total VA
rating of the transformer(s) shall not exceed the VA rating of the timer.

Limited Warranty

(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within
one year after purchase. For warranty service, return unit to place of purchase or mail to Lutron at
7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED
WARRANTY OF MERCHANTABILITY IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY
DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE
RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION.
THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON'S
LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE
MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE
PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to
state. Some states do not allow the exclusion or limitation of incidental or consequential damages, or
limitation on how long an implied warranty may last, so the above limitations may not apply to you.
This product is covered under one or more of the following U.S. patents: 7,190,125; 7,365,282;
7,546,473 and corresponding foreign patents. U.S. and foreign patents pending. Lutron, Claro, Maestro
and Satin Colors are registered trademarks, and FASS is a trademark of Lutron Electronics Co., Inc.
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts.
© 2009 Lutron Electronics Co., Inc.
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in the U.S.A.
6/09 P/N 030-1041 Rev. A
Lutron Technical Support Center
Installation
1 1
Turning OFF power.
• Turn power OFF at circuit breaker (or remove fuse).
2 2
Removing wallplate and
switch.
®
• Remove the wallplate and switch mounting screws.
• Carefully remove switch from wall (do not remove wires).
Shock Hazard. May result in serious injury or
WARNING
death. Turn off power at circuit breaker before
installing unit.
Turn screws
to loosen.
3 3
Disconnecting switch wires.
Important Note:
Your wall switch may have two wires attached to the same screw (see
illustrations below for examples). Tape these two wires together before
disconnecting. When wiring, connect wires to the Timer the same way they
were connected to the switch.
One wire in
the push-in
terminal hole
and one to
the screw.
Screw Terminals:
Push-in Terminals:
Turn screws to loosen.
Insert screwdriver.
Pull wire out.
Important Wiring Information
When making wire connections, follow the recommended strip lengths and
combinations for the supplied wire connector. Note: All wire connectors
provided are suitable for copper wire only. For aluminum wire, consult an
electrician.
Trim or strip wallbox wires to the length indicated by the strip gauge on the back of the control
Push-in Terminals: Insert wires fully.
NOTE: Push-in terminals are for use with 14 AWG
(1.5 mm
2
) solid copper wire only. DO NOT use stranded or
twisted wire.
OR
Screw Terminals: Tighten securely.
Screw terminals are for use with 12 or 14 AWG
) solid copper wire only. DO NOT use
(2.5 or 1.5 mm
2
stranded or twisted wire.
Wire Connector:
Twist wire
Use to join one 12 AWG or 14 AWG
connector
(2.5 or 1.5 mm
2
) ground wire with one
tight.
18 AWG (0.7 mm
2
) control ground wire.
1.800.523.9466
24 hrs / 7 days
4 4
Wiring.
• For installations involving more than one control in a wallbox,
refer to Multigang Installations before beginning.
Brass screw
Brass screw
Ground
Green wire
Reference Wiring Diagram
Timer
Light or
Brass
Fan
Fixture(s)
Live
Brass
120 V~
60 Hz
Neutral
Green wire
Ground
Wallbox
5 5
Mounting Control(s) to wallbox.
• Form wires carefully into wallbox, mount and align control(s).
• Install the wallplate(s
).
Note: Do not overtighten mounting screws. Permanent damage
can be caused by overtightening mounting screws.
Align control and
Start screws.
tighten screws.
One
continuous
wire to the
screw.
6 6
Turning ON power.
• Turn power ON at circuit breaker (or replace fuse).
Looped Wire:

Troubleshooting

Turn screw to
loosen.
Symptom
Possible Cause
Load does not turn
• Front Accessible Service Switch (FASS
ON or no LEDs turn
Timer is pulled out to OFF
ON.
• Light bulb(s) burned out.
• Breaker is off or tripped.
• Wiring error. Call
Lutron Technical Support Center
Load turns on and off
• Load draws less than 0.3 A or 40 W
repeatedly.
• Improper load connected
Technical Assistance
?
If you have questions concerning the installation or operation of this
product, call the Lutron Technical Support Center . Please provide
exact model number when calling.
U.S.A. and Canada (24 hrs/7days)
1.800.523.9466
México
+1.888.235.2910
Other countries 8am – 8pm ET
+1.610.282.3800
www.lutron.com
Wiring the Timer:
• Using the wire connector
provided, connect the green
ground wire on the Timer to the
bare copper or green ground
wire in the wallbox.
• Connect either of the wires
removed from the switch to one
of the brass screw terminals on
the Timer, or insert fully into the
push-in terminal.
• Connect the remaining wire
removed from the switch to the
other brass screw terminal on
the Timer, or insert fully into the
push-in terminal.
Operation
Tap Button Options
Snap on Claro
• Tap once when unit is off
wallplate.
Controlled load turns ON
and countdown timer begins.
When time expires, load turns OFF.
• Tap once when unit is on -
Controlled load turns OFF
and countdown timer resets.
• Tap twice quickly -
Controlled load turns on with
30 minute countdown timer.
FASS - Front Accessible
Service Switch
One Minute Indication:
When only one minute of time is remaining, the load will briefly turn off and on to give
an indication the timer is about to turn off.
) on
TM
IMPORTANT NOTICE:
To replace bulb, remove power by pulling the FASS switch out on the Control.
For any procedure other than routine bulb replacement, power must be
disconnected at the main electrical panel.
Tap Button Options
• Tap once when unit is off
Controlled load turns ON
and countdown timer begins.
When time expires, load turns OFF.
• Tap once when unit is on -
Controlled load turns OFF
and countdown timer resets.
• Tap twice quickly -
Controlled load turns on
without a time limit
Fax +1.610.282.6311
FASS - Front Accessible
Service Switch
http://www.lutron.com
To learn about the Advanced Features of Maestro Wall Controls including locked preset
and timer bypass disable, please visit: www.lutron.com/maestro/advfeatures or call
the Lutron Technical Support Center at 1.800.523.9466.
MA-T530G
Press to increase time
Press to reduce time
LEDs
• Orange LEDs indicate
timer duration or
remaining time in
minutes
• Bottom LED blinks
slowly to indicate 1
minute of time
remaining.
MA-T51
Press to increase time
Press to reduce time
LEDs
• Orange LEDs indicate
timer duration or
remaining time in
minutes
• Top green LED labeled
On has no time limit
• Bottom LED blinks
rapidly to indicate 1
minute of time
remaining.

Advertisement

loading

Summary of Contents for Lutron Electronics Maestro MA-T51

  • Page 1: Countdown Timer

    7,546,473 and corresponding foreign patents. U.S. and foreign patents pending. Lutron, Claro, Maestro U.S.A. and Canada (24 hrs/7days) remaining. and Satin Colors are registered trademarks, and FASS is a trademark of Lutron Electronics Co., Inc. Fax +1.610.282.6311 Wire Connector: FASS - Front Accessible 1.800.523.9466...
  • Page 2 E.U.A. y Canadá (24 horas/7 días a la semana) Fax +1.610.282.6311 pendientes. Lutron, Claro, Maestro, Satin Colors y FASS son marcas registradas de Lutron Electronics Conector de cable: Co., Inc. NEC es una marca registrada de National Fire Protection Association, Quincy, Massachusetts.

This manual is also suitable for:

Maestro ma-t530g