Sanyo PDG-DET100L Service Manual page 44

Hide thumbs Also See for PDG-DET100L:
Table of Contents

Advertisement

Electrical Adjustment
n Wind Sensor calibration
1. Enter the service mode.
. Select group no. "240" and item no. "2". Confirm the
Data value is "1".
0: Wind sensor function Disable
1: Wind sensor function Enable
3. Select group no. "240" and item no. "0".
4. To start the adjustment, change data value from "0"
to "1". After the auto-calibration completed, "OK" will
appear on the screen.
IMPORTANT
Before taking this adjustment, you need to replace the air
filter with new one or scroll up the filter sheet and make
sure the cabinet top, filter cover and filter cartridge are
securely installed.
m Lens shift Centering setting
1. Set the motorized lens shift to the center position
(horizontal and vertical) by using the LENS SHIFT Up/
Down, Left/Right buttons.
. Enter the service mode, select group no. "200" and
item no. "15" .
3. Change data value from "0" to "10". The centering po-
sition of the lens shift is memorized.
4. To check the lens shift operation correctly, move the
lens to your desired position with LENS SHIFT but-
tons. Then press the LENS SHIFT button for more
than 5 seconds. The lens moves to the memorized
center position automatically.
-44-

Advertisement

Table of Contents
loading

Table of Contents