Sanyo VCC-HD5400P Service Manual page 13

Hide thumbs Also See for VCC-HD5400P:
Table of Contents

Advertisement

Dsc Calibration
Infinity calibration :
AF_I_WIDE: 24
AF_I_MID1: 23
AF_I_MID2: 23
AF_I_MID3: 23
AF_I_MID4: 14
AF_I_MID5: 5
AF_I_MID6: -4
AF_I_TELE: -15
QR_Z_WIDE: -86
QR_F_I_WIDE: 131
QR_F_I_TELE: -304
QR_Z_AORI: -86
QR_F_I_AORI: 131
IRIS_GAIN: 94
IRIS_OFFSET: 14
Adjustment value determination is effectuated using below val-
ues.
The adjustment values fulfill the conditions below, they are
determined as within specifications.
Adjustment value determination
AF_I_WIDE: ZIW
ZIW: infinity adjustment value of focus at zoom position
wide (-126<=ZIW<=110)
AF_I_MID1: ZIM1
ZIM1: infinity adjustment value of focus at zoom position
middle1 (-138<=ZIM1<=121)
AF_I_MID2: ZIM2
ZIM2: infinity adjustment value of focus at zoom position
middle2 (-132<=ZIM2<=114)
AF_I_MID3: ZIM3
ZIM3: infinity adjustment value of focus at zoom position
middle3 (-128<=ZIM3<=209)
AF_I_MID4: ZIM4
ZIM4: infinity adjustment value of focus at zoom position
middle4 (-165<=ZIM4<=241)
AF_I_MID5: ZIM5
ZIM5: infinity adjustment value of focus at zoom position
middle5 (-232<=ZIM5<=300)
AF_I_MID6: ZIM6
ZIM6: infinity adjustment value of focus at zoom position
middle6 (-280<=ZIM6<=342)
AF_I_TELE: ZIT
ZIT: infinity adjustment value of focus at zoom position
tele (-230<=ZIT<=324)
QR_Z_WIDE: QRZW
QRZW: adjustment value of zoom written on QR code
(-102<=QRZW<=-75)
QR_F_I_WIDE: QRFW
QRFW: adjustment value of focus position wide written on
QR code (-63<=QRFW<=261)
x
OK
Copy
-
13
3. Lens Adjustment (1m)
Camera
Adjustment location: Focus of computer screen
Measuring location: Computer screen
Measuring equipment: Siemens star chart (A3)
Preparation:
Fluorescent light illumination with no flicker (incandescent
light cannot be used.)
Illumination above the subject should be 700 lux ± 10%.
Note:
Do not vibrate during the adjustment.
If readjusting after it has already been adjusted, wait for 15
minutes or more for the unit to cool down first.
Adjusting method:
1. It turns on power.
2. Set the siemens star chart 100 ± 1.0 cm from lens surface
so that it becomes center of the screen (zoom wide and
tele). Set the camera and the chart in a straight, and do
not put optical systems (mirror and conversion lens etc.)
3. Connect the camera's USB terminal to the computer'
USB connector.
4. Double-click on the DscCalDi.exe.
5. Click the "Focus", and Click the "Yes".
6. Lens adjustment value will appear on the screen.
7. Click the OK.
DscCalDi
Focus Result
!
AF_TEMP_AD: 445
AF_WIDE: 9
AF_MID1: 11
AF_MID2: 15
AF_MID3: 25
AF_MID4: 26
AF_MID5: 24
AF_MID6: 19
AF_TELE: 17
OK
-
Siemens
200 cm
100 ± 1.0 cm
star chart
x

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Vcc-hd5400pcVcc-hd5400

Table of Contents