2) Press the refresh mode button (4) until the
refresh mode indicator (5) flashes.
Refresh mode ends automatically after
approx. 8 hours for NiMH battery packs or
after approx. 12 hours for NiCd battery packs.
The battery pack is then fully charged.
Note: The battery pack can be removed from
the charger at any time, thereby interrupting
refresh mode.
When the operating indicator (2) lights up
continuously, this signals the end of refresh
mode. The battery pack can remain in the
battery charger and is therefore always ready
for use.
7.4
Charging vehicle starter batteries
(ACS 15 Plus only)
Only suitable for 6 V or 12 V wet
batteries with a minimum of 20 Ah.
Vehicle starter batteries can be charged in
combination with the charging adapter
6.27067 (not included in scope of delivery).
Read the directions for use and safety
instructions accompanying the charger
adapter.

8 Fault

8.1
Warning display (3) lights up
continuously
Battery pack is not charged.
Excessive/Insufficient temperature. When the
temperature of the battery pack is between
0 °C and 50 °C, the charging process begins
automatically.
8.2

Warning display (3) flashes

• Battery pack is defective. Remove the
battery pack immediately from the charger.
• Short circuit between the charging contacts.
Check charging compartment for foreign
bodies.
• For Li-Ion battery packs (with 14.4 V and
18 V): During charging, the button for
displaying the charge level was pressed.
First take the battery pack out of the charger
and then press the button on the battery pack.
8

9 Repairs

Repairs to the charger must only be carried
out by qualified electricians.
If the mains connection cable of this tool is
damaged, in order to prevent endangering
personnel and property it must be replaced by
the manufacturer, or the Customer Service of
the manufacturer, or a similarly qualified
person.
Metabo chargers requiring repairs can be sent
to the address on the next to the last page.
Please enclose a description of the fault with
the power tool.

10 Environmental Protection

Metabo's packaging can be 100% recycled.
Worn out chargers and accessories contain
considerable amounts of valuable raw and
plastic materials, which can be recycled.
These instructions are printed on chlorine-free
bleached paper.

11 Technical Specifications

See page 2.
A = Voltage ranges
of the battery packs
B = Charging current
1)
C = Charging time
a function of the
battery pack capacity
D = Charge current with conservation
charging
1)
Depending on the residual capacity and the
temperature of the battery pack, real charging
times may deviate from the specifications.
Changes due to technological progress
reserved.
as

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs 15Ac 30Ac 30 plus

Table of Contents