Select the preset position, then click Add. The selected
preset position is added in the Sequence list. Repeat this
procedure to specify the preset positions in sequence.
You can check the preset position by clicking Call.
To delete the preset position, click to select it in the list
and then click Delete.
To change the order in the list, select the preset position
and then click Move up or Move down.
To delete all preset position, click Delete All.
Speed
Select the speed of camera movement between 1 and 23,
or Fastest from the drop-down list. The camera moves
faster with a higher number setting. The fastest speed is
obtained with Fastest.
Stay time
Type a period of time during which the camera is to stay
at each preset position, between 1 and 3600 seconds.
Preview
Previews the order of movements of the selected tour.
The operation speed and stop time do not influence the
preview operation.
Stop
Stops the preview in action.
OK/Cancel
See “Buttons common to every menu” on page 20.
Serial Tab
Perform settings to control the camera according to data
which is input by peripheral devices via an external
serial interface. This unit complies with the Pelco-D
protocol. Make the settings according to the peripheral
devices connected to the network.
Standard
Select RS422, RS485 (half-duplex) or RS485 (full-
duplex).
Termination
Select the checkbox if you want to terminate it.
Camera ID
Specify the Camera ID of this unit.
OK/Cancel
See “Buttons common to every menu” on page 20.