2.17 [11] Maintenance
Value Range
2400 bps, 4800 bps, 9600 bps, 19200 bps, 38400 bps, 57600 bps, 115200 bps
Maintenance Console Location
2.17.1 [11-1] Main
Programming Manual References
2.17.1 [11-1] Main—RS-232C—Communication—Flow
Feature Guide References
1.26.1 Station Message Detail Recording (SMDR)
Communication—NL Code
Specifies the NL (New Line) code for the printer or personal computer.
If the printer or personal computer automatically feeds lines with a carriage return, select CR
(Carriage Return). If not, select CR+LF (Line Feed).
Value Range
CR+LF, CR
Maintenance Console Location
2.17.1 [11-1] Main
Programming Manual References
None
Feature Guide References
1.26.1 Station Message Detail Recording (SMDR)
Communication—Parity Bit
Selects a parity bit code that indicates what type of parity is used to detect an error in the string of
bits composing a character.
Make an appropriate selection depending on the requirements of the printer or personal computer.
Value Range
None, Mark, Space, Even, Odd
Maintenance Console Location
2.17.1 [11-1] Main
Programming Manual References
None
Feature Guide References
1.26.1 Station Message Detail Recording (SMDR)
782