Wsw18; Selectors 2 And 3: Detection Enabled Time For Cng Or "No Tone"; Selector 6: Registration Of Station Id; Selectors 7 And 8: Tone Sound Monitoring - Brother DCP6690CW Service Manual

Hide thumbs Also See for DCP6690CW:
Table of Contents

Advertisement

Selector
No.
Registration of station IDs of PCs
1
sharing a FAX machine
2
Detection enabled time for CNG or
"no tone"
3
4
Not used.
5
6
Registration of station ID
7
Tone sound monitoring
8

• Selectors 2 and 3: Detection enabled time for CNG or "no tone"

After the line is connected via the external telephone or by picking up the handset of the
machine, the machine can detect a CNG signal or "no tone" for the time length specified by
these selectors. The setting specified by these selectors becomes effective only when
selector 8 on WSW20 is set to "1."

• Selector 6: Registration of station ID

Setting this selector to "0" permits the registration of station ID for Austrian and Czech
models.

• Selectors 7 and 8: Tone sound monitoring

These selectors set monitoring specifications of the tone sound inputted from the line.

WSW18

(Function setting 3)
Function
App. 4-23
Setting and Specifications
0: Permitted
No. 2 3
0 0 :
40 sec.
0 1 :
0 sec. (No detection)
1 0 :
5 sec.
1 1 :
80 sec.
0: Permitted
No. 7 8
0 0 :
No monitoring
0 1 :
No monitoring
1 0 :
Up to phase B at the
calling station only
1 1 :
All transmission phases
both at the calling and
called stations
1: Prohibited
1: Prohibited
sec.: second(s)
Confidential

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfc6490cwMfc6890cdw

Table of Contents