Wsw02; Tone Signal Transmission Time Length And Min. Pause In Tone Dialing; Selectors 5 Through 8: Attenuator For Pseudo Ring Backtone To The Line - Brother DCP6690CW Service Manual

Hide thumbs Also See for DCP6690CW:
Table of Contents

Advertisement

Selector
No.
1
Tone signal transmission time
length
2
3
Min. pause in tone dialing
4
5
Attenuator for pseudo ring
backtone to the line (selectable in
|
the range of 0-15 dB, in 1 dB
8
increments)
• Selectors 1 through 4: Tone signal transmission time length and Min. pause in tone dialing
These selectors set the tone signal transmission time length and minimum pause in tone
dialing.
(Example: If "1," "2," "3," "4," and "5" are dialed.)

• Selectors 5 through 8: Attenuator for pseudo ring backtone to the line

These selectors are used to adjust the sound volume of a ring backtone in the F/T mode, an
on-hold sound, or a beep generated as a signal during remote control operation or at the
start of ICM recording.
The larger the value specified by these selectors, the greater the attenuation.

WSW02

(Tone signal setting)
Function
App. 4-5
Setting and Specifications
No. 1 2
0 0 :
70 ms
0 1 :
80 ms
1 0 :
90 ms
1 1 :
100 ms
No. 3 4
0 0 :
70 ms
0 1 :
80 ms
1 0 :
90 ms
1 1 :
140 ms
0: 0 dB
0: 0 dB
0: 0 dB
0: 0 dB
1: 8 dB
1: 4 dB
1: 2 dB
1: 1 dB
ms: millisecond(s)
Confidential