15. ABSOLUTE POSITION DETECTION SYSTEM
(e) Electromagnetic brake output
During ABS data transfer (for several seconds after the servo-on (SON) is turned on), the servo
motor must be at a stop.
Set "1
1 " in parameter No. 1 of the servo amplifier to choose the electromagnetic brake interlock
(MBR).
Y1
X1
ABS transfer
Brake (MBR)
mode
(f) Positioning completion
To create the status information for servo positioning completion.
During ABS data transfer (for several seconds after the servo-on (SON) is turned on), the servo
motor must be at a stop.
Y1
X0
ABS transfer
Positioning
mode
completion
Y1
ABS transfer
mode
(g) Zero speed
To create the status information for servo zero speed.
During ABS data transfer (for several seconds after the servo-on (SON) is turned on), the servo
motor must be at a stop.
Y1
X1
ABS transfer
Zero speed
mode
Y1
ABS transfer
mode
(h) Torque limiting
To create the status information for the servo torque limiting mode.
During ABS data transfer (for several seconds after the servo-on (SON) is turned on), the torque
limiting must be off.
Y1
X2
ABS transfer
Torque limiting mode
mode
Electromagnetic brake output
Y4
Completion of servo positioning
M
Servo zero speed
M
Servo torque limiting mode
M
15 - 46