15. ABSOLUTE POSITION DETECTION SYSTEM
1) The ready (RD) is turned ON when the ABS transfer mode (ABSM) is turned OFF after
transmission of the ABS data.
While the ready (RD) is ON, the ABS transfer mode (ABSM) input is not accepted.
2) Even if the servo-on (SON) is turned ON before the ABS transfer mode (ABSM) is turned ON,
the base circuit is not turned ON until the ABS transfer mode (ABSM) is turned ON.
If a servo alarm has occurred, the ABS transfer mode (ABSM) is not received.
The ABS transfer mode (ABSM) allows data transmission even while a servo warning is
occurring.
3) If the ABS transfer mode (ABSM) is turned OFF during the ABS transfer mode, the ABS
transfer mode is interrupted and the ABS time-out warning (AL.E5) occurs.
4) The functions of output signals such as ZSP, TLC, D01, and INP change depending on the
ON/OFF state of the ABS transfer mode (ABSM).
Note that if the ABS transfer mode (ABSM) is turned ON for a purpose other than ABS data
transmission, the output signals will be assigned the functions of ABS data transmission.
Symbol
Pin No.
(Note)
CN1B-4
D01
ZSP
CN1B-19
TLC
CN1B-6
(Note)
CN1A-18
INP
Note. CN1B-4 and CN1A-18 output the same signals. (To enter the positioning completion signal into INPS of the A1SD75,
connect CN1A-18.)
ABS transfer mode (ABSM): OFF
Positioning completion
Zero speed
During torque limit control
Positioning completion
15 - 9
Output signal
ABS transfer mode (ABSM): ON
ABS data bit 0
ABS data bit 1
Send data ready
ABS data bit 0

Hide quick links: