Mitsubishi Electric MELSERVO MR-J2S- A Instruction Manual page 247

General-purpose ac servo general-purpose interface servo amplifier
Table of Contents

Advertisement

13. OPTIONS AND AUXILIARY EQUIPMENT
MR-JCCBL2M-L
MR-JCCBL5M-L
MR-JCCBL2M-H
MR-JCCBL5M-H
Drive unit side
P5
19
LG
11
P5
20
LG
12
P5
18
LG
2
MR
7
MRR
17
MD
6
MDR
16
BAT
9
LG
1
(Note)
Plate
SD
Note. Always make connection for use in an absolute position detection system.
This wiring is not needed for use in an incremental system.
When fabricating an encoder cable, use the recommended wires given in Section 13.2.1 and the
MR-J2CNM connector set for encoder cable fabrication, and fabricate an encoder cable as shown
in the following wiring diagram. Referring to this wiring diagram, you can fabricate an encoder
cable of up to 50m(164.0ft) length including the length of the encoder cable supplied to the servo
motor.
When the encoder cable is to be fabricated by the customer, the wiring of MD and MDR is not
required.
Refer to Chapter 3 of the servo motor instruction manual and choose the encode side connector
according to the servo motor installation environment.
Encoder side
Drive unit side
7
P5
LG
P5
LG
P5
LG
8
1
MR
2
MRR
4
MD
5
MDR
3
BAT
LG
Plate
9
SD
Drive unit side
P5
LG
P5
LG
P5
LG
MR
MRR
BAT
LG
SD
Note. Always make connection for use in an absolute position detection system.
This wiring is not needed for use in an incremental system.
MR-JCCBL10M-L
to
MR-JCCBL30M-L
Encoder side
19
7
11
20
12
18
2
8
7
1
17
2
6
4
16
5
9
3
1
(Note)
9
For use of AWG22
Encoder side
(3M)
19
7
11
20
12
18
2
8
7
1
17
2
9
3
1
(Note)
9
Plate
13 - 22
MR-JCCBL10M-H
to
MR-JCCBL50M-H
Drive unit side
Encoder side
P5
19
LG
11
P5
20
LG
12
P5
18
LG
2
MR
7
MRR
17
MD
6
MDR
16
BAT
9
LG
1
(Note)
Plate
SD
7
8
1
2
4
5
3
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j2-super seriesMr-j2s-*aMr-j2s- a seriesMr-j2s-20a

Table of Contents