12. CHARACTERISTICS

12. CHARACTERISTICS

12.1 Overload protection characteristics

An electronic thermal relay is built in the servo amplifier to protect the servo motor and servo amplifier
from overloads. Overload 1 alarm (AL.50) occurs if overload operation performed is above the electronic
thermal relay protection curve shown in any of Figs 12.1. Overload 2 alarm (AL.51) occurs if the
maximum current flew continuously for several seconds due to machine collision, etc. Use the equipment
on the left-hand side area of the continuous or broken line in the graph.
In a machine like the one for vertical lift application where unbalanced torque will be produced, it is
recommended to use the machine so that the unbalanced torque is 70% or less of the rated torque.
1000
100
During stop
10
1
0.1
0
50
100
(Note) Load ratio [%]
a. MR-J2S-10A to MR-J2S-100A
10000
1000
During servo lock
100
10
1
0
50
100
(Note) Load ratio [%]
c. MR-J2S-500A MR-J2S-700A
Note. If operation that generates torque more than 100% of the rating is performed with an abnormally high frequency in a servo motor
stop status (servo lock status) or in a 30r/min or less low-speed operation status, the servo amplifier may fail even when the
electronic thermal relay protection is not activated.
During rotation
150
200
250
During rotation
150
200
250
Fig 12.1 Electronic thermal relay protection characteristics
1000
100
10
1
0.1
0
50
300
b. MR-J2S-200A to MR-J2S-350A
10000
1000
100
During servo lock
10
1
300
0
d. MR-J2S-11KA to MR-J2S-22KA
12 - 1
During rotation
During stop
100
150
200
(Note) Load ratio [%]
During rotation
100
200
(Note) Load ratio [%]
250
300
300

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j2-super seriesMr-j2s-*aMr-j2s- a seriesMr-j2s-20a

Table of Contents