Specifications - Mitsubishi Electric DX-ZD6UE Installation And Operation Manual

Hdd extension unit
Table of Contents

Advertisement

Specifications
General
Rated Power Supply:
Rated Input:
Operating Temperature:
Relative Humidity:
Altitude:
Dimensions:
Weight:
Control terminals
CONT IN
CONT OUT
GND (Ground)
TEMP ALM
FAN ALM
HDD ALM
CONT IN
CONT OUT
EXTERNAL CONTROL:
When set to ON: Power is supplied to the HDD when 12V is applied to the input terminal linked with the power supply.
When set to OFF: Power is always supplied to the HDD.
Serial bus terminal
Serial bus terminal (2 terminals)
Accessories:
USB2.0 cable
Control cable
Screws
User's manual (this manual)
Power cord
Control input/output terminals and circuits
TEMP ALM terminal
FAN ALM terminal
HDD ALM terminal
• Output Circuit
Output terminal
GND terminal
<Interface circuit inside the unit>
Design and specifications are subject to change without notice.
20
100 to 240 V AC, 50/60 Hz
0.75 - 0.4 A (100-240 V)
41 °F-104 °F (5 °C to 40 °C)
Max. 80 (%)
Max. 2000 (m)
424 (Width) x 361 (Depth) x 49 (Height) (mm)
6.3 kg (with 2 HDD mounted)
Input terminal linked with the power supply of the recorder
Output terminal linked with the power supply of the recorder
(CONT OUT is the through output of CONT IN.)
For grounding
Output terminal for detecting abnormal temperature (open collector output)
Active: "Low" level voltage output, Max. current 7 mA DC.
Non active: Open, Max. voltage 24 V DC.
Output terminal for detecting fan error (open collector output)
Active: "Low" level voltage output, Max. current 7 mA DC.
Non active: Open, Max. voltage 24 V DC.
Output terminal for detecting HDD error (open collector output)
Active: "Low" level voltage output, Max. current 7 mA DC.
Non active: Open, Max. voltage 24 V DC.
Reserved.
Reserved.
(Only DX-ZD6UE is connectable.)
1
1
8
1
3

Advertisement

Table of Contents
loading

Table of Contents