Page of 16

Mitsubishi PAC-YG60MCA Installation Instructions Manual: Confirmation Of Parts; Specifications; Product Specifications; External View

Air conditioner network system pi controller.
Hide thumbs

Advertisement

3

Confirmation of Parts

• Confirm that the box contains the following parts.
Number
1
2
* In addition to the parts mentioned above, other parts need to be procured locally in order to operate this device. Furthermore, other Mitsubishi optional
parts may be required depending on how the device is to be used.
For details, refer to "6 Installation Method".
4
Specifications
4-1. Product Specifications
Item
Power Supply
24 VDC±10%: 5 W
M-NET communication
Interface
Non-voltage a contact input
Temperature
Environment
Conditions
Humidity
Dimensions
200 (W) × 120 (H) × 45 (D) mm / 7
Weight
0.6 kg / 1 3/8 lb
Current Time
If the power is cut, the internal capacitor will normally keep counting the current time for approximately one week.
Backup during
(The internal capacitor takes approximately a day to charge. Replacement of a battery is not necessary.)
Power Failure
Installation
Inside a control panel (indoors)
Environment
* Use this product in a hotel, a business office environment or similar environment.
*1: Supply electric power from a power unit for the transmission line or an outdoor unit. Furthermore, the power consumption factor of the M-NET circuitry
of this device is "1/4" (equivalent to one ME Remote Controller).
*2: Supply electric power from the main unit to the contacts of the meters.
4-2. External View
Part Name
PI controller
Installation/instruction manual (this document)
Rating and Specification
17 to 30 VDC (*1)
Number of contacts: 4
Pulse signal:
a contact
Pulse width:
100 ms to 300 ms
(Idle period until next pulse: 100 ms or more)
100 ms or more
Rated voltage: 24 VDC
Rated current: 1 mA or less (*2)
Operating temperature range
Storage temperature range
30 to 90%RH (no condensation)
7
/
(W) × 4
3
/
(H) × 1
8
4
200
( 7
/
)
7
8
150
( 5
/
)
29
32
/
/
52
( 2
)
46.5
( 1
1
27
16
32
This device complies with Part15 of the FCC Rules.Operation is
subject to the following two conditions: (1)this device may not cause
harmful interference, and (2)this device must accept any interference
received, including interference that may cause undesired operation.
83.5
( 3
/
)
5
26
( 1
/
)
1
16
32
2
100 ms ~ 300 ms
0 to 40°C [32°F to 104°F]
-20 to 60°C [-4°F to 140°F]
25
/
(D) in
32
)
4.5
/
(
)
3
16
[ 24 VDC Power Supply]
27
( 1
/
)
3
32
Quantity
1
1
Screw terminal block (M3)
Screw terminal block (M3)
Screwless terminal block
/
45
( 1
)
25
32
/
9
(
3
)
8
Unit: mm (in)