Errors During The Start-Up Diagnostics - Epson Stylus Pro 5000 Service Manual

Color ink jet printer
Hide thumbs Also See for Stylus Pro 5000:
Table of Contents

Advertisement

5
Checking the RIP Station 5000 as a stand-alone unit

Errors during the Start-up diagnostics

When you turn on the RIP Station 5000 or reboot, the system goes through a series of
diagnostic tests that checks the motherboard. While the diagnostic tests are running, the
name of the test and a progress bar are displayed on the Control Panel.
If an error occurs during the Start-up diagnostics, the red activity light on the
RIP Station 5000 Control Panel flashes. At the end of the diagnostics, the red activity
light remains on and the Test Failed screen appears on the Control Panel. Select the line
selection button to the right of Details in the Test Failed screen for more information
about the test that failed.
When you encounter any of these conditions, turn off the RIP Station 5000 and inspect
the inside of the chassis for an obviously loose part or wire. Then check the other
components as suggested below. For all service, refer to "Accessing internal components"
on page 4-3. When you are done, refer to "Restoring functionality after service" on
page 4-11.
If the problems you experience are intermittent, you can also run RIP Station 5000
diagnostics manually. See "RIP Station 5000 diagnostic sets" on page 5-11 for details.
Table 5-1 lists the diagnostic tests that are run at startup, the corresponding error
numbers for a failed test, the area of the RIP Station 5000 being tested, and the suggested
corrective action for the failing test.
5-7