Earth Stove EARTHSTOVE 1500HT Installation And Operation Manual

Earth Stove EARTHSTOVE 1500HT Installation And Operation Manual

Milwaukee stove user manual

Advertisement

INSTALLATION AND OPERATION

MANUAL
EPA CERTIFIED
WOOD BURNING
STOVE
P
RETAIN THESE
INSTRUCTIONS
MODEL 1500HT
FOR FUTURE
REFERENCE
THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER. READ
ENTIRE MANUAL THOROUGHLY BEFORE INSTALLATION.
P/N 775001M, Rev. Q, 12/03

Advertisement

Table of Contents
loading

Summary of Contents for Earth Stove EARTHSTOVE 1500HT

  • Page 1: Installation And Operation

    INSTALLATION AND OPERATION MANUAL EPA CERTIFIED WOOD BURNING STOVE RETAIN THESE INSTRUCTIONS MODEL 1500HT FOR FUTURE REFERENCE THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER. READ ENTIRE MANUAL THOROUGHLY BEFORE INSTALLATION. P/N 775001M, Rev. Q, 12/03...
  • Page 2: Important Warnings

    Train them to stay a safe distance from the unit. box baffle brick properly installed. the stove. Do not use grates, irons or any other method to elevate the fire. stove (or see Safety/Listing Label on page 24). STOVE...
  • Page 3: Table Of Contents

    One - Installation and operation instructions manual One - Warranty Five - Baffle bricks One - Marble set (for stove top and ash lip) One - Insulation pad and strips. Place pad under top marble and strips under ash lip marble.
  • Page 4: Planning Your Installation

    SELECTING A LOCATION The design of your home and where you place your stove will determine its value as a source of heat. A wood stove depends primarily on air circulation (con- vection) to disperse its heat, and therefore, a central location is often best.
  • Page 5 B. 20 / 508 D. 8 / 203 Residential Standard (not approved for manufac- tured [mobile] homes) Using single wall pipe connector to the top of the stove. Clearances (inches / millimeters) A. 15 / 381 C. 15 / 381 B.
  • Page 6: Manufactured (Mobile) Home Requirements

    The firebox of the masonry structure must be of ade- quate size to allow a minimum of 6" (152 mm) clear- ance to the sides and top of the stove and 2" (51 mm) clearance to the rear. All stove models must be installed on their original listed legs or base unless otherwise specified by OMNI Testing Laboratory.
  • Page 7: Installation

    Regulations require that all stoves installed in manufac- tured (mobile) homes must be grounded. To do this simply attach a piece of No. 8 copper wire, at least 18" (457 mm) in length from the stove to the chassis of the manufactured (mobile) home. INSTALLING MARBLE ACCENTS Marble is a natural product and therefore each piece will have its own unique character.
  • Page 8 TOP VIEW OF BAFFLE BRICK SIDE VIEW OF BAFFLE BRICK TYPES OF CHIMNEYS The chimney is a vital part of your stove installation. A properly built masonry chimney or a properly installed factory built chimney will assure a consistent draft under a variety of weather conditions (a smoking stove is usu- ally caused by a chimney problem).
  • Page 9 Three (3) pre-drilled holes are provided in the flue collar for fastening the pipe securely to the stove. Use sheet metal screws to do this. Addi- tional sections of single wall pipe should be fastened together with at least three (3) sheet metal screws each section.
  • Page 10 INSTALLATION CHIMNEY HEIGHT REQUIREMENTS The chimney must extend 3 feet (914 mm) above the level of roof penetration and a minimum of 2 feet (610 mm) higher than any roof surface within 10 feet (305 cm) (see below). Check with your local building officials for any additional requirements for your area.
  • Page 11 INSTALLATION RESIDENTIAL STANDARD MANUFACTURED (MOBILE) HOME STANDARD Using 6” (152 mm) Diameter Single Wall Con- Using 6” (152 mm) Diameter Type L-Vent Connector Pipe nector Pipe Not Approved For Manufactured (Mobile) Home PAGE 11...
  • Page 12 Combustible Wall Chimney Connector Pass-Throughs NOTES: Connectors to a masonry chimney, excepting method B, shall extend in one continuous section through the wall pass-through system and the chimney wall, to but not past the inner flue liner face. A chimney connector shall not pass through an attic or roof space, closet or similar concealed space, or a floor, or ceiling. Where passage through a wall, or partition of combustible construction is desired, the installation shall conform to CAN/CSA-B365.
  • Page 13: Product Features And Controls

    This appliance is designed to provide a flow of air over the inside of the glass, which along with high heat helps keep it clean. When operating the stove on low for ex- tended periods of time, the glass may get dirty. A short, hot fire (15 - 20 minutes) will help clean off much of the normal buildup (see troubleshooting).
  • Page 14: Care And Operation

    PRIMARY AIR CONTROL This appliance is equipped with a control for the combustion air, located on the lower right side (front) of the stove. Slid- ing the control to the right increases the burn rate, to the left decreases the burn rate.
  • Page 15: Recommended Fuel

    Overfiring is a condition where excessive temperatures are reached, beyond the design capabilities of the stove. The damage that occurs from overfiring is not covered under the stove warranty. WARNING: BURNING IMPROPER FUEL (I.E.
  • Page 16: Maintenance

    SMALL AREA PAINT TOUCH-UP The stove body is painted with a quality high-temperature stove paint. Use only model TSPK-B Stove Paint, Catalog # 70K99. Do not touch-up your stove with any other paint. Using one small piece of 320 grit sand paper and lightly sand the blemish so that the edges are “feathered”...
  • Page 17 Replacing Glass: 1. Remove door from stove by lifting door up and off hinge pins: Place the door on a flat protected (towel) clean flat surface with the inside of the door facing up. Remove the glass clips (by removing screws holding clips), then care- fully remove broken glass one piece at a time (protective gloves are recommended).
  • Page 18: Troubleshooting

    5. Chimney diameter too large or too small to provide ade- quate draft. 6. The house is too airtight (usually takes 20 to 30 minutes for problem to appear as stove lowers air pressure in house). Crack a window open or provide an outside source of air near stove.
  • Page 19 Never burn the ap- pliance with the fuel door or ash drawer open or ajar. Do not operate this stove with the Air Control in the "open" position (pulled out) for extended periods. This wastes fuel and can cause dangerous overfiring condi- tions.
  • Page 20: Specifications

    Outside air provision Log length Flue position Flue collar size Width Depth Height (to flue) Height Stove back to flue center Approx. burn time Fuel capacity Firebox Size Maximum Burn Rate (BTU) EPA BTU Range EPA Efficiency Emissions Rate (grams/hour) Loading Approx.
  • Page 21: Replacement Parts List

    PART NO. DESCRIPTION Door Parts G6000 Door Assembly, Cast Black 14M72 Door Assembly, Gold 27M67 Clip Set, Glass 86-128 Door Gasket Kit, 3/4" Rope (includes adhesive) 27M81 Gasket, Glass Channel (Per Foot) G2000-7 Glass, Arched 9 1/2 X 15 3/4" (glass gasket not included) 10300 Handle Assembly (fits gold &...
  • Page 22 COMPONENT DIAGRAMS – Model 1500HT FIREBRICK Part/Catalog # Quantity FB-1 10545 01115 FB-5 BRICK DIAGRAM Dimensions Part/Catalog # 9 x 4 1/2” FB11 9 x 4 1/2” w/notch * Baffle brick are a special denser brick. Do not substi- tute * 9 x 4 1/2”...
  • Page 23: Optional Accessories

    Outside Air Floor Duct 14M72 DK100-G Gold Door Kit 14M22 BK-100 Blower Kit 14M21 Stove Stat Kit Thermally Controls 70K99 TSPK-B Touch-up Spray Paint Kit, Black Outside Air Floor Duct (Duct penetration measures 5 ¼” square) Gold Door Kit Blower Kit A Blower Kit (includes rheostat for variable speed control) 5 1/4"...
  • Page 24: Safety/Listing Label

    SAFETY/LISTING LABEL PAGE 24...
  • Page 25: Epa Label

    EPA LABEL PAGE 25...
  • Page 26: Ownership Records

    OWNERSHIP RECORDS Dealer’s Name: Dealer’s Address: City: Serial Number: Notes: SERVICE AND MAINTENANCE LOG Service Service Service Date Technician Description State: Date of Purchase: Page 26 Zip Code: Date Installed:...
  • Page 27 1110 West Taft Avenue Orange, CA 92865...

Table of Contents