Using the Charge/Analyze Pocket

1. Analyze/Charge Percentage of Original value
2. Analyze Dome switch
3. Analyze/Charge Pocket LED
The analyze/charge pocket is the one closest to the battery charger label and the Analyze dome switch. The analyze/charge
pocket can be used to:
• Charge a standard battery pack in less than four hours.
• Charge an Extended battery pack in less than 8 hours.
• Analyze a standard battery pack, ending with the battery pack fully charged, in less than twelve hours.
• Analyze an extended battery pack, ending with the battery pack fully charged, in less than 32 hours.
• Begin Analyzing
• Press the Analyze dome switch within 15 seconds of inserting the battery in the Analyze pocket to start the Analyze (Charge
– Discharge – Charge) process.
If the analyze dome switch is not pressed within 15 seconds, the battery will be charged, but not analyzed.
The Analyze progress LEDs indicate the battery capacity as a percent of the original value. When all LEDs are off, the
battery capacity is less than 50%.
Between 90%
When the Analyze dome switch has been pressed, the Analyze LED will illuminate Red to indicate that the battery testing
has started.
As the analysis proceeds and during the discharge activity, the four progress LEDs at the side of the battery pocket will
illuminate in sequence to indicate the capacity of the battery .
The Analyze LED is Green when the process is finished.
The battery is then ready for use provided the capacity is acceptable.
12 - 8
Between 80%
and 100%
and 90%
Green
Off
Green
Green
Green
Green
Green
Green
Between 70%
Between 50%
and 80%
and 70%
Off
Off
Off
Off
Green
Off
Green
Green
Less than 50%
Off
Off
Off
Off