4-1. Description

This multiprocess engine-driven welder and AC generator provides low speed generator AC power and DC weld out-
put for quiet, fuel-efficient operation. At 1800 rpm, this unit produces 5 kW/kVA 60 Hz 120/240 Volt AC generator
power. Achieve high quality Stick and TIG welding results at either 3000 or 3600 rpm. A special variable frequency
(60-120 Hz) receptacle provides 2.4 kW/kVA 120 Volt AC generator power continuously.

4-2. Weld, Power, And Engine Specifications

Rated
Welding
Welding
Mode
Output
280 A, 25 V, 100%
CC/DC
Duty Cycle
300 A, 25 V, 100%
CV/DC
Duty Cycle

4-3. Dimensions, Weights, and Operating Angles

Dimensions
Height
33 in (838 mm)
Width
18-3/4 in (476 mm)
Depth
45-1/2 in (1156 mm)
A
18 in (457 mm)
B
16-1/2 in (419 mm)
C
3/4 in (19 mm)
D
3-1/8 in (79 mm)
E
32-3/4 in (832 mm)
F
45-1/2 in (1156 mm)
G
13/32 in (10 mm) Dia.
Weight
590 lb (267 kg)
OM-4411 Page 10
SECTION 4 − SPECIFICATIONS
Maximum
Amperage
Open-Circuit
Range In
Voltage
CC Mode
72
20 − 300 A
50
− −
C
C
D
E
E
F
Engine End
Engine End
Voltage
Generator
Range In
Power Rating
CV Mode
5.5 kVA/kW (Peak)
5 kVA/kW (Continuous)
42/21 A,
120/240 V AC,
60 Hz,
Single-Phase at
1800 rpm
1800 rpm
10 − 33 V
10 − 33 V
And
2.4 kVA/kW, 20 A,
120 V AC,
60-120 Hz,
Single-Phase
At All Speeds
A
A
B
Y Do not exceed tilt angles or engine could
Y Do not move or operate unit where it could
G
4 Holes
25
25
800 426
Fuel
Engine
Capacity
Kohler CH-20
Air-Cooled,
Two-Cylinder,
10 gal
Four Cycle,
Four-Cycle,
(38 L)
(38 L)
20 HP Gasoline/LP
Tank
Engine
w/Electronic
Governor
be damaged or unit could tip
be damaged or unit could tip.
tip
tip.
25
25
803 129