Gas connection
This appliance must be installed
with its own shut off valve and the
included gas pressure regulator.
Both the valve and the regulator
must be easily accessible to the
consumer to turn on or shut off the
gas supply after the appliance is
installed.
This appliance and its individual
shut off valve must be disconnected
from the gas supply during any
pressure testing of the system
performed in excess of _' psi
(3.5 kPa). The machine must be
isolated from the gas supply line by
closing its individual manual shut off
valve at test pressures equal to or
less than _' psi (3.5 kPa).
Any pipe connections must be made
using a thread sealant approved for
gas connections.
Failure to correctly
install these items could lead to a
...... gas leak and subsequent explosion.
ANSI Z 21.1 for the USA
or
-
the current Can/CGA
i
Interim #58-M95
and _2 Insta!lation Codes for gas
.........................................
c
a.........
Make sure that the maximum gas
supply pressure, before the gas
pressure regulator, is never more than _/-
psi (3.5 kPa) for natural gas or LP gas.
The minimum supply pressure to get
the required gas input is
4" w.c. for natural gas
10" w.c. for LP gas.