Transition Networks E-FX-HB-0800 User Manual

100base-fx fast ethernet unmanaged fiber hub with tx or fx uplink

Advertisement

Quick Links

COMPLIANCE INFORMATION

UL Listed
C-UL Listed (Canada)
CISPR/EN55022 Class A
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant
to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference, in which case the user will be
required to correct the interference at the user's own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on
the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables
aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique
édicté par le ministère des Communications du Canada.
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes
Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen
werantwortlich ist.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des
interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques
appropriées
VCCI Class 1 Compliance
This equipment is in the 1st Class category (information equipment to be used in commercial and/or
industrial areas) and conforms to the standards set by the Voluntary Control Council For Interference by
Data Processing Equipment and Electronic Office Machines aimed at preventing radio interference in
commercial and/or industrial areas. When used in a residential area or in an adjacent area thereto,
interference may be caused to radio and TV receivers, etc. Read the instructions for correct handling.
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in
damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten
verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur
Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen
einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners.
Copyright Restrictions
© 1999 TRANSITION Networks.
All rights reserved. No part of this work may be reproduced or used in any form or by any means –
graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Printed in the U.S.A.
Unmanaged Fiber Hub with TX or FX Uplink
The stackable, rack-mountable E-FX-HB-1600 and E-FX-HB-0800 series
unmanaged Fast Ethernet
set up and to modify workgroups connected over fiber and to install an
optional copper or fiber backbone uplink connection to the workgroups
and/or optional connections for stacking up to five hubs.
E-FX-HB-1600, E-FX-HB-1600(SC)
9
STAT
ACT
BB
COL
STAT
PWR
GFT
ACT
1
The E-FX-HB-1600 hub provides sixteen (16) Fast Ethernet
fiber connections to terminal devices plus space for an optional copper or
fiber backbone uplink and space for an optional stacking adapter.
E-FX-HB-0800, E-FX-HB-0800(SC)
BB
COL
STAT
PWR
GFT
ACT
1
The E-FX-HB-0800 hub provides eight (8) Fast Ethernet
connections to terminal devices plus space for an optional copper or fiber
backbone uplink and space for an optional stacking adapter.
BACKBONE UPLINK ADAPTERS Optional devices ordered separately that, when
installed, provide one of the following Fast Ethernet
MA-FST
MA-FSC
MA-FSM
MA-TX
STACKING ADAPTERS Optional
devices ordered separately that, when
installed, allow stacking between E-FX-
HB-xx00 hubs.
ACC-0200
ACC-0201
33122.A

Fast Ethernet

100BASE-FX
E-FX-HB-1600, E-FX-HB-0800
USER'S GUIDE
fiber hubs allow the network administrator to
9
10
11
10
11
12
13
14
15
16
100BASE-FX
1
2
3
2
3
4
5
6
7
8
100BASE-FX
1
2
3
2
3
4
5
6
7
8
ST connector to multimode fiber
SC connector to multimode fiber
SC connector to singlemode fiber
RJ-45 connector to twisted-pair copper, AutoCross
E-FX-HB-xx00 in the Network . . . . .2
Installation . . . . . . . . . . . . . . . . . . . .4
Operation . . . . . . . . . . . . . . . . . . . .11
Fault Isolation and Correction . . . .12
Cable Specifications . . . . . . . . . . . .14
Stacking adapter
Technical Specifications . . . . . . . . .15
Stacking cable
Compliance Information . . . . . . . . .16
Minneapolis, MN 55344 USA
12
13
14
15
16
4
5
6
7
8
ST OR SC
4
5
6
7
8
ST OR SC fiber
backbone uplink connections:
feature

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E-FX-HB-0800 and is the answer not in the manual?

Questions and answers

Summary of Contents for Transition Networks E-FX-HB-0800

  • Page 1: Compliance Information

    E-FX-HB-0800, E-FX-HB-0800(SC) 100BASE-FX STAT The E-FX-HB-0800 hub provides eight (8) Fast Ethernet connections to terminal devices plus space for an optional copper or fiber backbone uplink and space for an optional stacking adapter. BACKBONE UPLINK ADAPTERS Optional devices ordered separately that, when...
  • Page 2: Technical Specifications

    E-FX-HB-0800(SC) Regulation: EMC Directive 89/336/EEC Purpose: To declare that the E-FX-HB-1600 or E-FX-HB-0800 to which this declaration refers is in conformity with the following standards. EMC-CISPR 22: 1985 Class A; EN 55022: 1988 Class A; EN 50082-1:1992; EN 60950 A4:1997; IEC 801.2, IEC 801.3, and IEC 801.4; IEC 950 I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
  • Page 3: Cable Specifications

    (DTE), repeater, and max: -9.0 dBm max: -14.0 dBm multi-port media converter port delays. If the result is less than or equal to 512 bit-times, the path is good. to hub, switch or router STAT 100BASE-FX STAT STAT 100BASE-FX STAT...
  • Page 4: Installation

    INSTALLATION Optionally Install Expansion Adapter WARNING: Remove AC line cord from power source before installing expansion adaptor in E-FX-HB-xx00. Failure to observe this warning could result in personal injury or death. CAUTION: Wear a grounding device and observe electrostatic discharge precautions when installing Expansion Adapter in the E-FX-HB-xx00.
  • Page 5: Fault Isolation And Correction

    FAULT ISOLATION and CORRECTION If the E-FX-HB-xx00 fails, isolate and correct the fault by determining the answers to the following questions and then taking the indicated action: Is the P(o)W(e)R LED on the E-FX-HB-xx00 illuminated? • Is the power cord properly installed in the E-FX-HB-xx00 and in the grounded AC outlet? •...
  • Page 6: Operation

    Install E-FX-HB-xx00 at Site WARNING: During the site installation, handle the E-FX-HB-xx00 in such a way that the E-FX-HB-xx00 does not fall. Failure to observe this warning could result in injury to personnel and/or equipment damage. NOTE: If E-FX-HB-xx00 is shipped with brackets installed, proceed to step 2. To install the E-FX-HB-xx00 in 19-inch rack cabinet: STAT 100BASE-FX...
  • Page 7 Power the E-FX-HB-xx00 NOTE: When the hub is connected to an AC outlet supplying 100-240VAC at 50-60 Hz, the hub automatically powers ON To power ON the E-FX-HB-xx00: Locate power receptacle at back of E-FX-HB-xx00. Plug unit end (female) of power cord into E-FX-HB-xx00 power receptacle.
  • Page 8 Optionally Connect to Backplane through TX Uplink NOTE: Refer to 512-bit rule (page 3) to keep cable lengths within acceptable bounds. To connect twisted-pair cable from E-FX-HB-xx00 100BASE-TX uplink adapter to network: Locate 100BASE-TX uplink adapter installed at E-FX-HB-xx00 back. (See page 5.) ™...

Table of Contents