Connect the cold water intake hose
(blue mark) to the cold water valve and
the hot water intake hose (red mark) to
the hot water valve.
If the machine is being connected to a
cold water supply
and cold water intake hoses must be
attached to the cold water valve
through the use of a Y adapter (avail-
able at a hardware store). Both hoses
be connected to a water source,
or the machine will not function prop-
erly.
connect the washer to hot
water only.
Turn on the valve(s) and check for
leaks. The water pressure must be
within 15-145 psi (1-10 bar). If the water
pressure is greater that 145 psi
(10 bar), a pressure reducer must be
installed. If the water pressure is below
15 psi (1 bar), there will not be enough
water available for a complete fill.
The water intake hoses are equipped
with screen filters. Please do not re-
move these filters except for cleaning.
42
, both the hot
Tips for a hot water connection
– The hot water temperature from the
hot water valve must not exceed
60°C, the ideal temperature is 55°C.
– If there is
water pressure at the
hot water inlet, the unit automatically
switches to cold water after several
minutes.