5. Install the fuel pump relay and fuse box
cover.
Fuel pump module check
1. Connect the YDIS.
2. Using the "Stationary test" of the YDIS, lis-
ten for the fuel pump module operation
sound.
3. Disconnect the fuel pump module coupler
"a".
4. Supply power to the ECM, and then mea-
sure the input voltage at the fuel pump
module coupler terminals (wire harness
end). Replace the fuel pump module if
within specification. Check the wire har-
ness if out of specification.
TIP:
After the power is supplied to the ECM, voltage
will only be applied to the fuel pump module for
3 seconds.
a
Input voltage
12 V (battery voltage)
Blue (L)–Black (B)
5. Remove the fuel pump module. See "Fuel
tank and fuel pump module" (4-9).
6. Measure the fuel sender resistance. Re-
place the fuel sender if out of specifica-
tions.
L
B
Y
A. Lower position
B. Upper position
Lower position resistance
133.5–136.5 Ω
Upper position resistance
5.0–7.0 Ω
7. Install the fuel pump module. See "Fuel
tank and fuel pump module" (4-9).
7-30
Fuel system
B
B
A