Download  Print this page

Sony DWR-R01D Operating Instructions Manual Page 22

Hide thumbs

Advertisement

Table of Contents
Connection Example of Word Clock and
Audio
For digital audio output to be performed correctly, it is
necessary to connect a device incorporating a sampling
rate converter to the DIGITAL OUT 1/2/3 connector of the
receiver or input a master word clock signal to the WORD
SYNC IN connector of the receiver and perform
synchronization.
There are the following two types of system for inputting
a master word clock signal to perform synchronization.
Note
If the number of connected devices is high, we do not
recommend cascade connections. We recommend using a
word clock divider.
Synchronization system example 1
This system connects the master word clock signal in
cascade via the WORD SYNC OUT connector of this
device.
Set the 75 Ω termination switch of only the DWR-R01D
unit at the end of the cascade connection to ON.
Master word clock
a) WORD SYNC IN
b) WORD SYNC OUT
c) Set the 75 Ω termination switch to OFF
d) Set the 75 Ω termination switch to ON
22
System Configuration Examples
Synchronization system example 2
This system divides the master word clock signal with a
divider, and then connects to each device.
Set the 75 Ω termination switches of all DWR-R01D units
to ON.
Master word clock
Word clock divider
a) WORD SYNC IN
b) Set the 75 Ω termination switches to ON