  • Page 1 Made in USA Made in USA Slim Line Rack UPS User’s Manual Models 3 & 4 www.mgeups.com...
  • Page 2 For service call: 1-800-438-7373 MGE UPS SYSTEMS 1660 Scenic Avenue Costa Mesa, CA 92626 (714) 557-1636 www.mgeups.com Revision History Esprit Rack UPS User's Manual 86-153301-03 Copyright © 2000 MGE UPS Systems All rights reserved. Printed in USA Revision A00 New Release 10/00...
  • Page 3 Safety Important Safety Instructions. Save These Instructions. This manual contains important safety instructions for the Esprit Models 3 and 4 that should be followed during installation and maintenance of the UPS and Batteries. Caution: Risk of electric shock, even with the unit disconnected from the AC power source.
  • Page 4 Caution: Do not dispose of batteries in a fire. The batteries may explode. Do not open or mutilate the batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. A battery can present a risk of electric shock and high short circuit current. The following precautions should be observed when working with batteries: Remove watches, rings, or other metal objects.
  • Page 5: Table Of Contents

    Rack Mounting ...3—1 3D. Optional Accessories ...3—1 3E. Connecting the Optional Extended Battery ...3—2 3F. Disconnecting the UPS & Battery to Take Out of Service ...3—2 3G. Connecting to the Communication Ports ...3—2 3H. Connecting the UPS to the Utility ...3—3 3I.
  • Page 6 2a. Rear View of Models 3 and 4 With Rack Kit and Extended Batteries...2—2 2b. Optional Rack Mounting Kit ...2—2 2c. Typical Front Views of Models 3, 4, Extended Battery, Label Placement ...2—2 3a. RS232, Contact Closures and Remote Shutdown...3—2 3b.
  • Page 7: Quick Start

    Please read this manual fully, to familiarize yourself with the safety instructions and Esprit features. MGE UPS Systems MGE, one of the largest UPS manufacturers in the world, has a power protection solution for every power problem.
  • Page 8 1—2...
  • Page 9: Getting To Know Your Esprit Rack Ups

    2. Getting to Know Your Esprit Rack UPS 2A. Product Features & Benefits Features Plug in operation Modular concept High efficiency 2/3 components reduction Many user selectable parameters Built-in receptacles Quiet operation Standard HID communications Network-based power management software Web management...
  • Page 10: Esprit Rack Ups Product Views With Rack Kit

    2C. Esprit Rack UPS Product Views With Rack Kit Figure 2a. Rear View of Models 3 and 4 With Rack Kit and Extended Batteries Model 3 Utilization en atmosphere controlee Intended for use in a controlled environment COM1 Utilización preuista en un amblento controlado.
  • Page 11: Installation

    3. Installation 3A. Storing the UPS and Recharging the Battery Always store the equipment in its original packaging. The battery is of the sealed lead-acid type. Battery recharge requires that the battery module be plugged into an energized NEMA 5-15 receptacle for 6-8 hours. The battery may be charged in the box by pulling the AC cord out through the bottom.
  • Page 12: Connecting The Optional Extended Battery

    +8 to +15VDC 3—2 1. Open 2. RTXD transmit (TX) 3. RRXD receive (RX) 4. OPEN 5. LOGIC RETURN (OV) 6. PNP (plug and play, do not use) 7. ALARM - Contact closure through a transistor from pin 7 to pin 5 when "low battery".
  • Page 13: Connecting The Ups To The Utility

    Plug the AC line cord of the UPS module into an AC 2-pole, 3-wire grounded receptacle for models 3 and 4. There should be no other loads on this branch circuit. To do so may result in a circuit overload. Refer to National Electrical Code (NEC) specifications for requirements in your area or ask your electrician.
  • Page 14: Solution-Pac Software

    Solution Pac software allows you to interface your computer with the UPS. The software is loaded on your computer and through the communication port, can access and react to status information from the UPS. Refer to the Solution Pac manual on the CD for a full description of its operation. 3—4...
  • Page 15: Startup And Shutdown

    UPS configures itself to run at the last frequency it detected in a previous power-up operation. " will be green. See Figure 4a. 6 Status LEDs Alarm 1. 2. 3. 4. 5. 6. Silence (Controls audible alarm & alarm/fault handling) 1. Inverter ON (UPS on battery power) 2.
  • Page 16: Battery Operation

    If desired, the UPS can be set up to operate at a known, fixed frequency regardless of the detected utility frequency. Fixed-frequency operation is often desirable in installations that make use of cold-start capability. Discussion on this is in the Advanced Configuration Section (section 6) of this manual.
  • Page 17 UPS has to run on battery power. Reduce the load. Utility power is present, stable and within acceptable voltage limits. In this state, the UPS will be operating on utility power mode. The UPS is operating on battery power. The inverter is running. 4—3...
  • Page 18: Button Operation

    The "Fault Detected" LED turns on and acts as described above for ANY system alarm, including those that have their own status indicators (e.g. overload, replace battery). Button Operation There are 3 buttons present on the front panel: The grey, " The green, "...
  • Page 19: Fault Alarms

    Output Overload Warning/Shutdown (long-long-long beep) UPS Action Warning when there is less than 3 minutes of back-up time remaining. shutdown. Could also indicate a faulty battery charger. There is a problem with the battery system. The battery system may not be plugged into an AC source or there is a charger problem.
  • Page 20 4—6...
  • Page 21: Performance And Product Specifications

    5. Performance & Product Specifications Table 5a. Esprit Models 3 and 4 Rack UPS Specifications Item Output VA Output W Surge protection, joule rating Waveform Nominal input voltage Maximum input voltage (VAC) Low voltage transfer (VAC) Low line return (VAC)
  • Page 22: Sizing Guide And Battery Runtimes

    Table 5a. Esprit Models 3 and 4 Rack UPS Specifications (Continued) Item Design standards Input connection Output connections Auxiliary DC input Size Weight MTBF Sizing Guide and Battery Runtimes Unix Server server PC Server server servers Esprit 3 SLR Esprit 3 SLR + 1 Ext.
  • Page 23: Advanced Configuration

    6. Advanced Configuration Esprit Front Panel Configuration Mode Usage and Instructions For advanced users only! The Esprit UPS is shipped from the factory with a configuration that is suitable for most applications. However, there are some circumstances where modification of the UPS operating parameters is required.
  • Page 24: Configuration Options

    It is possible to cycle backward through the configuration options by pressing and holding the top button. A given option setting can be forced to its factory default state by pressing and holding the bottom button. The middle (Power ON) button is not used in configuration mode. To leave configuration mode, simultaneously depress and hold in both the top and bottom buttons until the buzzer sounds and the AC PRESENT indicator stops flashing.
  • Page 25 — Indicators: ( ) = Option On/illuminated ( — ) = Option Off/dark Do not select the "Custom" setting (Option 3 & 4 both ON) unless you are instructed to do so by MGE service. Number of battery cabinets installed 2 (C) Esprit 3 &...
  • Page 26 Options 5, 6 – Input Voltage Tolerance Use these two option switches to select the Esprit’s sensitivity to low/high input voltage conditions. The Esprit will switch to battery power when the utility voltage falls outside the range selected. The percentages shown in the table below are subtracted/added to the nominal voltage setting as set by options 4, 5.
  • Page 27 Option 10 – Automatic UPS restart after Low Battery shutdown The factory setting for this option is ON, which allows the UPS to automatically turn its output back on following a Low Battery shutdown once input AC is present. This setting is the usual one for applications where the UPS is connected to automated or unattended equipment that is capable of restarting itself without direct human intervention.
  • Page 28 If the POIT is enabled, the UPS will power up the load from utility power, then briefly switch to battery power approximately 5-7 seconds after it is powered up. The UPS runs on battery for only 3-5 seconds, so no significant drain on the battery will occur.
  • Page 29: Service & Maintenance

    7A. Maintenance Clean the UPS with a dry cloth after turning off all power to the UPS and switching off the power switch. The UPS performs monthly automatic battery tests. However, it is recommended that a 6 month test be performed on the UPS for battery condition. Perform all tests off peak hours with applications shut down.
  • Page 30: Recycling Your Ups

    7B. Recycling Your UPS In USA or Canada, call 1-714-557-1636, M - F, 6:00 A.M. to 5:00 P.M. PST. Ask for a return goods authorization for free UPS or battery recycling. MGE does not cover return freight charges for recycling and will not accept items without a return goods authorization number. 7—2...
  • Page 31: Troubleshooting

    8. Troubleshooting Problem UPS does not turn on. There is no power to the computer load. Battery Online indicator remains on, even though line voltage is present. UPS beeps occasionally. UPS does not provide the expected backup time. Overload indicator flashes. Battery Fault indicator is lit.