Meyer Sound M3D Operating Instructions Manual page 30

M series line array loudspeaker
Hide thumbs Also See for M3D:
Table of Contents

Advertisement

Table 3. M3D-Sub Directional Subwoofer (continued)
Cooling
AC Power
AC power connector
Voltage selection
Safety agency rated
operating voltage
Turn on/turn off points
Current Draw
Idle current
Max. long-term continuous
current (>10 sec)
Burst current (<1 sec)
Ultimate short-term peak
current draw
Inrush current
RMS Network
Physical
Enclosure
Finish
Protective grill
Rigging
Weather protection
Dimensions
24 • M3D™ Line Array
Forced air cooling, four fans total, two ultra high-speed reserve fans
250VAC NEMA L6-20 (twistlock) inlet or IEC 309 male inlet
Optional VEAM connector (integrates AC, audio and network)
Automatic, two ranges, each with high-low voltage tap (uninterrupted)
95 VAC to 125 VAC, 208 VAC to 235 VAC, 50/60 Hz
85 VAC–134 VAC; 165 VAC–264 VAC
1.2Arms (115 VAC)
0.6Arms (230 VAC)
1.3ArmS (100 VAC)
18 Arms (115 VAC)
9 Arms (230 VAC)
20 Arms (280 VAC)
32 Arms (115 VAC)
16 Arms (230 VAC)
36Arms (100 VAC)
Note: AC power cabling must be of sufficient gauge so that under burst current conditions, cable
transmission losses do not drop voltage below specified operating range at the speaker.
50 A pk (115 VAC)
25 A pk (230 VAC)
57 A pk (100 VAC)
< 12 A at 115 VAC
Equipped for simple two conductor twisted-pair network, reporting all operating parameters of
amplifiers to operator's host computer.
Multi-ply hardwood
Black textured (weather protected)
Note: Custom color available upon request
Powder-coated hex stamped steel
QuickFly MRF-3D rigging frame with integral CamLinks, rear connecting bars and captive quick-release
pins
Standard
54" W x 20" H x 30.5" D (1372 mm x 508 mm x 762.5 mm)
Meyer Sound Laboratories Inc

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M3d-sub directional subwoofer

Table of Contents