ABLE OF ONTENTS Introduction Product Overview ... 1 Scanner and Accessories... 2 Scanner Components... 4 Caution and Serial Number Labels... 5 Stand Specifications ... 5 Cable Removal... 6 Cable Connection Warning... 6 Maintenance... 6 Installation RS232 or Light Pen ... 7 IBM 46xx or OCIA ...
Page 4
Design Specifications ... 27 Applications and Protocols ... 29 Default Settings - Communication Parameters... 30 Upgrading the Flash ROM Firmware ... 35 Scanner and Cable Terminations ... 36 Laser and Product Safety ... 40 Limited Warranty ... 42 Patents ... 43...
NTRODUCTION The Fusion is a hand-held, omnidirectional bar code scanner with optional single-line scanning capabilities. It utilizes the powerful Metrologic QuantumE scan engine to provide an outstanding scan performance on all standard 1D barcode symbologies, including RSS. Designed for retail applications, the Fusion includes additional key product features like: •...
NTRODUCTION Scanner and Accessories Part No. MS3780 Fusion Scanner 00-02099 MS3780 Installation and User’s Guide * 00-02407 MetroSelect * Guides also available for download at www.metrologic.com. Part No. AC to DC Power Transformer - Regulated 5.2VDC @ 650 mA output.
Page 7
NTRODUCTION Scanner and Accessories Part No. USB Full Speed Cable, Locking Plus-Power™Type A 53-53213x-N-3 3 m (10 ft.) straight cord, short strain relief USB Full Speed Cable, Locking Plus-Power™Type A 5 m (17 ft.) straight cord, short strain relief 53-53214x-N-3...
Gently wipe the scanner window. Cable Removal Disconnect the power supply from the PowerLink cable and turn off power to the host system before removing the cable from the scanner. Locate the small ‘pin-hole’ beneath the Fusion logo on the front side of the scanner near the end of the handle.
When the scanner first receives power the white LED will flash, one blue LED will turn on and the scanner will emit one beep. Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration setting are also required for proper communication to occur.
When the scanner first receives power the white LED will flash, one blue LED will turn on and the scanner will emit one beep. Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration setting are also required for proper communication to occur.
When the scanner first receives power the white LED will flash, one blue LED will turn on and the scanner will emit one beep. Powering the MS3780 directly from the host device can sometimes cause interference with the operation of the scanner or the computer.
When the scanner first receives power the white LED will flash, one blue LED will turn on and the scanner will emit one beep. Powering the MS3780 directly from the host device can sometimes cause interference with the operation of the scanner or the computer.
USB port. Turn on the host device. As a default, the MS3780-38 leaves the factory with USB Keyboard Emulation Mode enabled. For information on configuring the MS3780-38 for USB Serial Emulation Mode, please refer to the USB: Low Speed section of the...
NSTALLATION EAS Deactivation EAS D EACTIVATION SW1 and SW2 are the switch banks inside the CheckPoint Device that set the deactivation range. The following is a list of CheckPoint recommended switch bank settings. CheckPoint Recommended Switch Bank Settings SW1 & SW2 switches 1 and 6 set to ON All Fusion models equipped with EAS capabilities have an EAS designation in their model numbers.
CANNER PERATION The Scan Pattern Mode Select Button There are two configurable scan pattern modes available with the MS3780. • The primary scan pattern mode is the default scan pattern active when the scanner starts. By default, the primary scan pattern is set to all-scan-lines for omnidirectional reading.
CANNER PERATION How to Use CodeGate and the Manual Activation Mode For illustration purposes the unit’s scan pattern has been set to single-line (menu reading) mode. Figure 16. Factory Defaults: For information on how to change the factory defaults, refer to the MetroSelect Configuration Guide (00-02407).
PERATION Audible Indicators When the MS3780 is in operation, it can provide audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). For instruction on how to change the tone of the beeper, refer to the MetroSelect Configuration Guide (00-02407).
CANNER PERATION Visual Indicators There are four LEDs located on the top of the MS3780. When the scanner is on, the flashing or constant illumination of the LEDs indicates the status of the current scan and the scanner. Figure 18. LED Indicators...
Failure Mode Indicators Both Blue LEDs Flashing with One Emitted Razzberry Tone This indicates that the scanner has experienced a laser subsystem failure. Return the unit to a Metrologic authorized service center for repair. Both Blue LEDs and the White LED are Flashing with Two Emitted Razzberry Tones This indicates that the scanner has experienced a motor failure.
CANNER PERATION Depth of Field Specifications* Normal Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 19. Normal Depth of Field * All specifications are subject to change without notice.
CANNER PERATION Depth of Field Specifications* Reduced Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 20. Reduced Depth of Field * All specifications are subject to change without notice.
CANNER PERATION Depth of Field by Bar Code Element Width* Normal Scan Zone mils Figure 21. Normal Scan Zone by Bar Code Element Width * All specifications are subject to change without notice. INIMUM LEMENT IDTH...
CANNER PERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone mils Figure 22. Reduced Scan Zone by Bar Code Element Width * All specifications are subject to change without notice. INIMUM LEMENT IDTH...
CANNER PERATION IR Activation Range* Normal Figure 23. Normal IR Activation Range Reduced Figure 24. Reduced IR Activation Range * All specifications are subject to change without notice.
Make sure the cable is plugged into the scanner. Some host systems cannot supply enough current to power the MS3780. Use the power supply included with the scanner. Adjust the same symbol timeout for a longer time increment.
Page 28
The minimum symbol length setting does not work with the bar code. UIDE If the scanner is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that the host cable and host are supporting the handshaking properly. Verify that the scanner’s data format matches the format required by the host.
Page 29
There is a VLD failure. and the blue LED flashes. During power up the unit There is a scanner razzes twice motor failure. and both LEDs flash. RS232 Only The com port at the host is not working or...
Page 30
UIDE Check that the scanner and the host are configured for the same interface. Add some intercharacter delay to the transmitted output by using the MetroSelect Configuration...
7 tones or no beep Blue = laser on, ready to scan White = good read, decoding 10 position modular RJ45 connector Application Dependent 189 mm (7.44”) 65 mm (2.56”) 73 mm (2.88”) 195 g (6.9 oz.) MS3780 0.33 mm (13 mil) bar code...
Operating Temperature: Storage Temperature: Humidity: Contaminants: Ventilation: Shock: Specifications subject to change without notice. MS3780 5VDC ± 0.25V 1.375 W 1.0 W 275 mA typical at 5VDC 200 mA typical at 5VDC Class II; 5.2VDC @ 650 mA IEC 60825-1:1993+A1:1997+A2:2001 EN 60825-1:1994+A11:1996+A2:2001 FCC, ICES-003 &...
ERSION CANNER DENTIFIER MS3780 The MS3780 scanner with Built-in PC Keyboard Wedge Interface is designed to be used for keyboard emulation only. Many RS232 configurable functions (e.g. formatting) available in other Metrologic scanners are also available as keyboard wedge functions.
The scanner is shipped from the factory configured to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages. If an asterisk is not in the default column then the default setting is off or disabled.
Page 35
EFAULT ETTINGS ARAMETER Expanded ID “]e0” RSS Limited Enable RSS Limited ID “]e0” RSS Limited App ID “01” RSS Limited Check Digit Bars High as Code 39 Spaces High as Code 39 Bars High as Scanned Spaces High as Scanned DTS/SIEMENS DTS/NIXDORF NCR F...
Page 36
EFAULT ETTINGS ARAMETER Transmit UPC-A Check Digit Transmit UPC-E Check Digit Expand UPC-E Convert UPC-A to EAN-13 Transmit Lead Zero on UPC-E Convert EAN-8 to EAN-13 Transmit UPC-A Number System Transmit UPC-A Manufacturer Transmit UPC-A Item ID# Transmit Codabar Start/Stop Characters CLSI Editing (Enable) Transmit Mod 43 Check Digit on Code 39...
Page 37
EFAULT ETTINGS ARAMETER Nixdorf ID LRC Enabled UPC Prefix UPC Suffix Transmit AIM ID Characters STX Prefix ETX Suffix Carriage Return Line Feed - disabled by default in KBW Tab Prefix Tab Suffix “DE” Disable Command “FL” Laser Enable Command DTR Handshaking Support RTS/CTS Handshaking Character RTS/CTS...
Page 38
EFAULT ETTINGS ARAMETER Supplements are not Required Two Digit Redundancy Five Digit Redundancy 100 msec to Find Supplement Programmable in 100msec steps (MAX 800 msec) Coupon Code 128 Programmable Code Lengths Programmable Prefix Characters Programmable Suffix Characters Prefixes for individual Code Types Editing Inter Scan-Code Delay...
The user merely connects the scanner to a serial port on the PC, launches the MetroSet2 program, and blasts off to new software upgrades. Each MS3780, regardless of the version number or communication protocol, can be upgraded. In other words, all RS232 (-41), keyboard wedge (-47), light pen (-41), OCIA (-9), IBM 468X/469X (-11), low speed USB (-38), and integrated full speed USB (-40) units can be upgraded.
CANNER AND ABLE Scanner Pinout Connections The MS3780 scanner interfaces terminate to a 10-pin modular socket. The serial # label indicates the interface enabled when the scanner is shipped from the factory. Keyboard Wedge and Stand-Alone Keyboard MS3780-47 Function Ground...
CANNER AND ABLE Cable Connector Configurations (Host End) Keyboard Wedge PowerLink Cable 53-53002x-3 Function Keyboard Clock Keyboard Data No Connect Power Ground +5 Volts DC Function PC Data No Connect Power Ground +5 Volts DC PC Clock No Connect Metrologic will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other.
Non guardate mai il raggio laser, anche se credete che lo scanner non sia attivo. Non aprite mai lo scanner per guardare dentro l’apparecchio. Facendolo potete esporVi ad una esposizione laser rischiosa.
ASER AND RODUCT Notices This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Page 45
CANNER AND ABLE Cable Connector Configurations (Host End) RS232 PowerLink Cable 53-53000-3 Function Shield Ground RS232 Transmit Output RS232 Receive Input DTR Input/Light Pen Source Power/Signal Ground Light Pen Data CTS Input RTS Output +5VDC USB Power/Communication Cable 53-53213x-N-3, 53-530214x-N-3 or 53-53235x-N-3 Function PC +5V/V_USB...
The MS3780 Fusion™ scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The MS3780 Fusion scanners have a five (5) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS3780 Fusion scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S.
ATENTS Patent Information This METROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No.; 5,216,232; 5,260,553; 5,340,971; 5,340,973; 5,424,525; 5,468,951; 5,484,992; 5,525,789; 5,528,024; 5,557,093; 5,591,953; 5,616,908; 5,627,359; 5,637,852; 5,661,292; 5,767,501; 5,777,315; 5,789,730; 5,789,731; 5,796,091; 5,811,780; 5,825,012; 5,828,048; 5,844,227; 5,883,375;...
Need help?
Do you have a question about the MS3780 Fusion and is the answer not in the manual?
Questions and answers