Abbreviated Ascii Table - Honeywell IS4921 Integration Manual

Area imaging decode engine
Table of Contents

Advertisement

Example 2:
The following sample illustrates the serial command sequence for configuring the engine for the
factory default settings, disabling Code 128 scanning, and adding a "G" as a configurable prefix.
Commands for features that require sequences of multiple bar codes for activation (i.e. prefixes,
suffixes, and timeout features) should be sent in the same order that they are normally scanned.
Feature
Enter Configuration Mode
Load Defaults
Disable Code 128
Configure Prefix #1
Code Byte 0
Code Byte 7
Code Byte 1
Exit Configuration Mode

Abbreviated ASCII Table

Character
[STX]
[ETX]
[ACK]
[NAK]
0
1
2
3
4
5
6
7
8
9
Host Command
ASCII Representation
[stx]999999[etx]
02h 39h 39h 39h 39h 39h 39h 03h
[stx]999998[etx]
02h 39h 39h 39h 39h 39h 38h 03h
[stx]100113[etx]
02h 31h 30h 30h 31h 31h 33h 03h
[stx]903500[etx]
02h 39h 30h 33h 35h 30h 30h 03h
[stx]0[etx]
02h 30h 03h
[stx]7[etx]
02h 37h 03h
[stx]1[etx]
02h 31h 03h
[stx]999999[etx]
02h 39h 39h 39h 39h 39h 39h 03h
Hex Value
02h
03h
06h
15h
30h
31h
32h
33h
34h
35h
36h
37h
38h
39h
Engine
Response
[ack] or 06h
[ack] or 06h
[ack] or 06h
[ack] or 06h
[ack] or 06h
[ack] or 06h
[ack] or 06h
[ack] or 06h
Decimal Value
2
3
6
21
48
49
50
51
52
53
54
55
56
57
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Is4920

Table of Contents