CD SECTION
CD section adjustments are done automatically in this set.
In case of operation check, confirm that focus bias.
FOCUS BIAS CHECK
1. Connect the oscilloscope between IC501 pin #¡ (TP552 (RF))
and GND on Main board.
2. Insert the disc (YEDS-18). (Part No. : 3-702-101-01)
3. Press the ^ button.
4. Confirm that the oscilloscope waveform is as shown in the
figure below. (eye pattern)
A good eye pattern means that the diamond shape (
center of the waveform can be clearly distinguished.
• RF signal reference waveform (eye pattern)
VOLT/DIV : 200 mV (10 : 1 probe in use)
TIME/DIV : 500 nS
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensitivity.
Test Point:
– MAIN BOARD (SIDE A) –
BLK
BLK
RED
VIO
SECTION 4

ELECTRICAL ADJUSTMENTS

) in the
RF level :
0.8-1.8 Vp-p
BLU
BLU
EXCEPT
D-193
TP552
(RF)
D-193
EXCEPT
D-193
– 6 –