Electrolux ETGC24R0MKS Instruction Manual page 19

Table of Contents

Advertisement

Available languages

Available languages

35 electrolux gas installation
Gas installation
01. This cooktop was designed for use
with LPG/NG gas .
02. Always use a pressure regulator
exclusive for your gas cooktop. The
lack of pressure regulator might
cause excess of pressure and leak
of gas. Always check for the validity
of the pressure regulator. Hose and
regulator should be replaced every
5 years.
Technical specification of the
pressure regulator:
• Pressure: 200 mm C. A.
• Max. consumption: 2 kg/h
03. Always use a PVC hose to work
from -20ºC to 100ºC. Be sure that
hose:
• does not have joins.
• does not go on the back of the
gas cooktop neither close to the
hot air exits.
• its less than 125cm long.
04. If possible, install the gas cylinder
outside the kitchen, in a place
protected and with air flow.
05. Use a 1/2"metallic hose to connect
to the gas cooktop using a L
coupling connector.
06. Only use a plastic hose when this
one does not go on the back of the
gas cooktop.
Pressure regulator
Metalic flexible tube
L coupling
connector
Hose installation
01. Place the metal clamp on the hose
end.
02. Connect the hose to the oven
connector and tight the clamp.
03. Place the other clamp on the
opposite hose end and connect it
to the pressure regulator. Tight the
clamp.
04. Bolt the pressure regulator to the
gas cylinder carefully.
05. After the installation, check if there
is any gas leak, using soap or
liquid detergent foam
gas installation electrolux 36
If you have any doubt or need to buy
any accessory for the installation,
please contact our authorize service.

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents