30" (76.2 cm) double oven gas ranges
Hide thumbs Also See for KFGD500ESS:
Table of Contents

Advertisement

Available languages

Available languages

Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
The floor anti-tip bracket must be installed. To install the anti-
tip bracket shipped with the range, see "Install Anti-Tip
Bracket" section.
Grounded electrical supply is required. See "Electrical
Requirements" section.
Proper gas supply connection must be available. See "Gas
Supply Requirements" section.
Contact a qualified floor covering installer to check that the
floor covering can withstand at least 200°F (93°C).
Use an insulated pad or ¼" (0.64 cm) plywood under range if
installing range over carpeting.
IMPORTANT: To avoid damage to your cabinets, check with your
builder or cabinet supplier to make sure that the materials used
will not discolor, delaminate or sustain other damage. This oven
has been designed in accordance with the requirements of UL
and CSA International and complies with the maximum allowable
wood cabinet temperatures of 194°F (90°C).
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280). When such standard is not
applicable, use the Standard for Manufactured Home
Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this range must conform with the
current standards CAN/CSA-A240-latest edition, or with local
codes.
Mobile home installations require:
When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the standards
listed above.
4
Product Dimensions
A**
F
³⁄₄
¹⁄₈
A. 35
" ±
" (90.8 ± 0.3 cm)
cooktop height (minimum)
with leveling legs screwed
all the way in
B. Model/serial/rating plates
(located behind the control
panel)*
*Model/serial/rating plates may be rotated up from behind the
control panel for viewing from the front of the range.
**Range can be raised approximately 1" (2.5 cm) by adjusting
the leveling legs.
***Excludes handle. Dimension given is from wall to front of oven
door and will vary based on electrical outlet receptacle
installation.
B*
C**
D
E***
³⁄₈
¹⁄₈
C. 47
" ±
" (120.3 ± 0.3 cm) overall
height (minimum) with leveling
legs screwed all the way in**
¹⁄₂
¹⁄₄
D. 28
" ±
" (72.4 ± 0.6 cm) depth
with handle
¹⁄₈
¹⁄₈
E. 26
" to 27¼" ±
" (66.4 to
69.2 cm ± 0.3 cm)***
¹⁵⁄₁₆
¹⁄₁₆
F. 29
" ±
" (76.0 ± 0.2 cm) width

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents