1 - 4
MC75A Enterprise Digital Assistant Integrator Guide
Scan/Decode
Charging/Battery
LED
Status LED
LED Indicators
Figure 1-3
LED Charge Indicators
Table 1-2
Charging/Battery
Status LED
Off
Slow Blinking Amber
(1 blink every 2 seconds)
Solid Amber
Fast Blinking Amber
(2 blinks/second)
Charging Spare Batteries
See
Chapter 2, Accessories
Charging Temperature
Charge batteries in temperatures from 0°C to 40°C (32°F to 104°F). Note that at temperatures above 35°C (95°F),
charging is intelligently controlled by the MC75A and the charging accessory in order to ensure safe operation and
optimize long-term battery life.
To accomplish this, for small periods of time, the MC75A or accessory alternately enables and disables battery
charging to keep the battery at acceptable temperatures. The MC75A or accessory indicates when charging is
disabled due to abnormal temperatures via its LED. See
Powering On the MC75A
Press the Power button to turn on the MC75A. If the MC75A does not power on, perform a warm boot. See
Resetting the MC75A on page
Radio Status LED
(MC75A6/8 only)
MC75A is not charging.
MC75A is not inserted correctly in the cradle or connected to a power source.
Charger/cradle is not powered.
MC75A is charging.
Charging complete.
Note: When the battery is initially inserted in the MC75A, the amber LED flashes
once if the battery power is low or the battery is not fully inserted.
Charging error, e.g.:
•
Temperature is too low or too high.
•
Charging has gone on too long without completion (typically eight hours).
for information on using accessories to change spare batteries.
1-5.
Indication
Table
1-2.