HSU129HG(DB)-SM
Service Diagnosis
7.3.7 EEPROM abnormal
Indoor Display
E4
Indoor EEPROM error
F12 Outdoor EEPROM error
LED1 flash 1 times
Method of
The Data detected by the EEPROM are used to determine MCU.
Malfunction
Detection
Malfunction
When the Data of EEPROM is error or the EEPROM is damaged.
Decision
Conditions
Supposed
Faulty EEPROM data
Causes
Faulty EEPROM
Faulty PCB
Troubleshooting
* Caution Be sure to turn off power switch before connect or disconnect connector, or
parts damage may be occurred.
Check the EEPROM of the indoor or outdoor mainboard , and be sure it is right.