QUANTA Rackgo X Series F03A Technical Manual page 153

Superior serviceability 4 x compute node 2u server
Table of Contents

Advertisement

T
ROUBLESHOOTING
Table 4: Hardware Failure Troubleshooting Matrix (Continued)
F
AILURE
Uncorrectable
ECC
Single bit cor-
rectable ECC
DIMM
Multi-bit cor-
rectable ECC-
system will
reboot
No boot
a. No power
b. HDD not
ready, HDD
HDD
size 0
c. Read/write/
SMART/bed sec-
tor
Over temp. spec N/A
CPU
No boot
Reboot
Fusion-IO card
Un-recognized
S
E
C
YMPTOM
RROR
ODE
A0-47, B0-B7
N/A
N/A
N/A
N/A
N/A
H
F
ARDWARE
AILURE
S
UGGESTIONS
1. Plug the debug card to
check if the system can
boot into PXE server.
2. Refer to the EDAC
instruction.
1. Verify HDD power cable
is plugged in, if it's the
swap HDD first.
1. Verify the HDD data
cable is plugged in firmly
a) Change the data cable
first, then HDD
b) If cable and HDD are
replaced, but still have
same issue.
c) The M/B "HDD
interface may be
bad.
REPLACE MB
1. Replace HDD first
2. If the issue still same, M/
B "HDD interface error".
REPLACE MB
1.Verify fans and CPU heat-
sink
2. If it looks fine, change
CPU first
3. if the issue still
same,mark the M/B "CPU
temp over spec". Contact
Quanta and or Facebook
for further instruction
Make sure use one CPU on
CPU0 location can boot up
or not.
Should not have this issue.
Use VGA card to confirm
the VGA, if the card cannot
display, the M/B "PCI-E slot
has issue".
REPLACE MB
T
M
ROUBLESHOOTING
ATRIX
R
EMARK
6-6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents