H
F
ARDWARE
AILURE
Motherboard fails single bit ECC Errors
Normally, the M/B will not automatic to report user the single bit error, check the SEL log
to see if any ECC had happened.
SEL example below:
SEL Record ID : 0002
Record Type : 02
Timestamp : 11/19/2011 18:12:30
Generator ID : 0033
EvM Revision : 04
Sensor Type : Memory
Sensor Number : 63
Event Type : Sensor-specific Discrete
Event Direction : Assertion Event
Event Data : a00010 A4
Description : Correctable ECC
Table 3: Mapping Table
EVENT DATA 3
00
01
08
09
10
11
18
19
20
21
28
29
30
31
38
39
6-3
MEMORY LOCATION
A0
A1
A2
A3
A4
A5
A6
A7
B0
B1
B2
B3
B4
B5
B6
B7
T
ROUBLESHOOTING