Evaporator Fan Motor; Condenser Fan Motor - Whirlpool ACP102PR Manual

10,000 btu portable room air conditioner
Table of Contents

Advertisement

Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

EVAPORATOR FAN MOTOR

Refer to page 4-9 for the procedure for access-
ing the evaporator fan motor.
1.
Unplug air conditioner or disconnect power.
2.
Disconnect the fan motor wires from the
control board and capacitor terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the in-
dicated fan motor wire connectors. The
meter should indicate as follows:
Red & red = between 125 and 145 Ω.
Yellow & black = between 25 and 45 Ω.
White & black = between 60 and 80 Ω.
Yellow & white = between 95 and 115 Ω.
One red & white = between 125 and 145 Ω.
Other red & white = continuity
Electrical Shock Hazard

CONDENSER FAN MOTOR

Refer to page 4-18 for the procedure for ac-
cessing the condenser fan motor.
1.
Unplug air conditioner or disconnect power.
2.
Disconnect the fan motor wires from the
control board and capacitor terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the in-
dicated fan motor plug pins and wire con-
nectors. The meter should indicate as fol-
lows:
Motor Wires
Red & red = between 80 and 105 Ω.
Motor Plug Pins
Yellow & black = between 25 and 45 Ω.
White & black = between 30 and 50 Ω.
Yellow & white = between 60 and 80 Ω.
Motor Wires & Plug Pin
One red & white = between 80 and 105 Ω.
Other Red & white = continuity
5-3