Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug air conditioner or disconnect power.
2.
Remove the cabinet from the unit (see
page 4-2 for the procedure).
3.
Position the unit with the rear of the unit
facing you.
4.
Remove the room temp thermistor from
the mounting clip.
Room Temp
Thermistor
REMOVING THE EVAPORATOR
5.
Pull the mounting clip off the evaporator
tubing and reinstall it on the replacement
evaporator at the same location.
Pull Clip Off Evaporator
6.
Remove the two screws from the louver
motor and remove the motor.
Louver Motor Screws
7.
Unhook the right end, pull the left end out
of the housing hole, and remove the lou-
ver from the top of the unit.
4-22
Unhook Louver