Table 1: Security Actions and associated Phantom Buttons (Partition 1)
This table illustrates the various possible actions from a security system and the phantom buttons they will activate depending on Time of
Day. The recommended phantom button scene name is also matched to the phantom button number.
Security Action
Arm Away
Arm Stay
Disarm
Intrusion
Emergency
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems
Time of Day
Phantom Button(s) Activated
Day
Night
Day
Night
Day
Night
Day
Night
Day
Night
95 + 92
95 + 92
-
93
92 turned off
92 turned off; 94
98 + 99
98 + 99
100 + 98
100 + 98
Phantom Button Scene Name
Away Scene + Away Timeclock Mode
Away Scene + Away Timeclock Mode
-
Goodnight
(Away Timeclock turned off)
(Away Timeclock turned off); Welcome
Exterior Flash, Interior Full
Exterior Flash, Interior Full
Emergency, Exterior Flash
Emergency, Exterior Flash