Sign In
Upload
Manuals
Brands
Emerson Manuals
Cell Phone
Rosemount 375
Emerson Rosemount 375 Manuals
Manuals and User Guides for Emerson Rosemount 375. We have
6
Emerson Rosemount 375 manuals available for free PDF download: User Manual, Getting Started, Upgrade Procedures
Emerson Rosemount 375 User Manual (118 pages)
FIELD COMMUNICATOR
Brand:
Emerson
| Category:
Cell Phone
| Size: 4.62 MB
Table of Contents
Table of Contents
3
Table of Contents
5
Introduction
11
Section 1
11
Using this Manual
11
Section 2
13
Learning the Basics
13
Overview
13
Safety Messages
13
Installing the System Card and the Battery Pack
14
Starting up and Shutting down
15
Shutting down
15
Basic Features and Functions
17
Using the Keypad
18
On/Off Key
18
Arrow Navigation Keys
18
Enter Key
18
Tab Key
18
Alphanumeric Keypad
19
Backlight Adjustment Key
19
Function Key
20
Multifunction LED
20
Using the Touch Screen
20
Using the Soft Input Panel (SIP) Keyboard
21
Viewing the 375 Main Menu
21
Running the Settings Menu
22
About 375
22
Backlight
23
Clock
23
Contrast
23
Event Capture
24
License
25
Memory
25
Power
25
Touch Screen Alignment
26
Exit to the 375 Main Menu
26
Starting the Fieldbus Application
22
Starting the HART Application
22
Communicating with a PC
26
Irda Communication with Pcs
26
Listen for PC
27
Transferring HART Configurations Using AMS Suite: Intelligent Device Manager
28
Easy Upgrade Programming Utility
28
Using the Scratchpad Application
29
Create a New Document
30
Open an Existing Document
30
Enter Text
30
Select Text
30
Cut Text
31
Copy Text
31
Paste Text
31
Undo Text
31
Save a Document
31
Save a Copy
32
Delete a Document
32
Exiting Scratchpad
32
Managing Storage
33
Types of Storage
33
Maintenance
34
Battery Information
34
Checking the Charge Remaining
34
Charging the Battery
35
Removing the System Card and Battery Pack
35
Running a Self Test
36
Working in an Intrinsically Safe (IS) Area
36
Waste Disposal
36
HART Functionality
37
Section 3
37
Overview
37
Safety Messages
37
Basic Features and Functions
38
Interpreting the HART Icon
38
Using Fast Key Sequences
38
Setting up Hot Key Options
39
Executing Hot Key Options
40
Removing Hot Key Options One at a Time
40
Removing All Hot Key Options
40
Starting the HART Application
38
Working Offline
41
Creating New Configurations Offline
41
Opening Saved Configurations Offline
43
Edit a Saved Configuration Offline
44
Copy a Saved Configuration Offline
45
Send a Saved Configuration Offline
45
Delete a Saved Configuration Offline
45
Rename a Saved Configuration Offline
46
Compare Two Saved Configurations Offline
46
Working Online
47
Connecting to a HART Loop
49
Viewing the Online Menu
50
Viewing the Device Setup Submenu
52
Process Variables (PV)
52
Diagnostics and Service
52
Basic Setup
53
Detailed Setup
53
Review
53
Primary Variable (PV)
54
Analog Output (AO)
54
Lower Range Value (LRV)
54
Upper Range Value (URV)
54
Viewing the Utility Menu
54
Configuring the HART Application
54
Changing the HART Polling Option
54
Changing Ignored Status Messages
56
Storage Cleanup
56
Viewing Available Device Descriptions
57
Simulating an Online Connection to a HART Device
57
Viewing HART Diagnostics
58
DC Voltage Measurement (HART Terminals)
58
Disconnecting from a HART Device
58
Fieldbus Functionality
59
Overview
59
Safety Messages
59
Basic Features and Functions
60
Link Active Scheduler (LAS)
60
Interoperability
61
Operation with Other Hosts
61
St_Rev
61
Modes
62
Types of Modes
62
Locating Mode Parameters
63
Changing Modes
63
Permitted Modes
63
Starting the Fieldbus Application
64
Working Online
65
Connecting to a Fieldbus Loop
65
Bench Hook-Up
67
Field Hook-Up
68
Displaying the Live Device List
69
Displaying the Block List
71
Working with Device Blocks
71
Parameter Functionality
71
Changing and Sending Parameter Data
72
Running Methods
73
Displaying Device Status
73
Other Block List Selections
73
Detail Menu
73
Changing the I/O Block Schedule
74
Displaying Advanced Features
75
Utility
75
Polling
75
Viewing Installed Fieldbus Device Descriptions
76
Fieldbus Diagnostics
76
Disconnecting from a Fieldbus Device
77
Section 5
79
Troubleshooting Suggestions
79
Overview
79
Loops
80
Sample Values
81
Error and Status Messages
83
Required Information for Technical Assistance
87
Contacting Technical Support Personnel
88
APPENDIX A Reference Information
89
Processor and Memory Specifications
89
Memory
89
Microprocessor
89
Internal Flash
89
System Card
89
Ram
89
Expansion Module
89
Physical Specifications
89
Weight
89
Keypad
90
Connection Specifications
90
Battery Charger
90
HART and Fieldbus Communication
90
Personal Computer
90
Power Supply Specifications
90
Power Supply Voltage
90
Battery
90
Battery Operating Time
90
Power Supply/Charger
90
Environmental Specifications
91
Usage
91
Charge
91
Storage
91
Storage Without Batteries
91
Enclosure Rating
91
Shock
91
Ordering Information
92
Spare Parts List
93
APPENDIX B Approval Information
95
Overview
95
Approved Manufacturing Locations
95
European Directive Information
95
Electro Magnetic Compatibility (89/336/EWG
95
ATEX Directive (94/9/EC) (KL Option Only
95
Other Important Guidelines
95
Hazardous Locations Certifications (KL Option Only
95
North American Certifications
96
Factory Mutual (FM
96
Canadian Standards Association (CSA
96
European Certifications
97
ATEX Intrinsic Safety
97
HART Intrinsically Safe Electrical Parameters
97
Foundation Fieldbus
97
Label Drawings
98
Approval Drawing
100
Glossary
105
Index
111
Advertisement
Emerson Rosemount 375 User Manual (140 pages)
Field Communicator
Brand:
Emerson
| Category:
Cell Phone
| Size: 3.87 MB
Table of Contents
Table of Contents
3
Table of Contents
5
Section 4
9
Introduction
9
Section 1
9
Fieldbus Functionality
9
Using this Manual
9
Section 2
11
Learning the Basics
11
Overview
11
Safety Messages
11
Product Overview and Precautions
12
Field Communicator Components
12
Working in an Intrinsically Safe (IS) Area
13
Battery and Power Supply/Charger Overview
14
Guidelines and Precautions
14
Check the Charge Remaining
15
Charge the Battery
15
Maintaining the Battery Life and Performance
17
Installing the System Card and the Battery
18
Removing the Battery and the System Card
19
Starting up and Shutting down
19
Starting the 375 Field Communicator
19
Entering Stand-By
20
Shutting down the 375 Field Communicator
20
Basic Features and Functions
21
Using the Keypad
22
Using the Touch Screen
24
The 375 Main Menu
25
Starting the HART Application
25
Starting the Fieldbus Application
25
Running the Settings Menu
25
Communicating with a PC
31
Using Scratchpad
34
Managing Storage
37
Types of Storage
37
Free Memory on a System Card
38
Maintenance
38
Running a Self Test
38
Calibrating
39
Waste Disposal
39
Hazardous Substances
39
HART Functionality
41
Section 3
41
Overview
41
Safety Messages
41
Basic Features and Functions
42
Using a Fast Key Sequence
42
Starting the HART Application
42
Working Offline
43
Creating New Configurations
43
Opening Saved Configurations
44
Working Online
48
Connecting to a HART Loop
48
Displaying the Online Menu
51
Saving an Online Device Configuration
52
Displaying the Device Setup Submenu
52
Displaying Graphics
54
Using Hot Keys
55
Setting up Hot Key Options
55
Executing a Hot Key Option
56
Removing a Hot Key Option
56
Removing All Hot Key Options
56
Configuring the HART Application
57
Changing the HART Polling Option
57
Changing Ignored Status Messages
59
Changing the Menu Title
59
Storage Cleanup
60
Viewing Available Device Descriptions
60
Simulating an Online Connection to a HART Device
61
Running HART Diagnostics
62
DC Voltage Measurement (HART Terminals)
62
Disconnecting from a HART Device
62
Overview
63
Safety Messages
63
Basic Features and Functions
64
Link Active Scheduler (LAS)
64
Device Interoperability
65
LAS Hierarchy
65
St_Rev
65
Starting the Fieldbus Application
66
Working Online
67
Connecting to a Fieldbus Segment
67
Bench Hook-Up
69
Displaying the Live Device List
71
Displaying the Block List
72
Displaying a Device Menu
72
Modes
73
Working with Device Blocks
76
Displaying Graphics
82
Configuring the Fieldbus Application
83
Changing the Fieldbus Polling Addresses
83
Changing the Slot Time
83
Viewing Available Device Descriptions
84
Running Fieldbus Diagnostics
85
DC Voltage and Noise Level Measurement
85
Signal Level Measurement
85
Disconnecting from Afieldbus Device
86
Section 5
87
Troubleshooting Suggestions
87
Overview
87
Error and Status Messages
92
Required Information for Technical Assistance
96
APPENDIX A Reference Information
97
Processor and Memory Specifications
97
Microprocessor
97
Memory
97
Power Supply/Charger Specifications
98
Physical Specifications
98
Connection Specifications
98
Battery Specifications
100
Temperature Specifications
100
Order Information
101
Spare Parts List
103
Product Certifications
105
Appendix B
105
Overview
105
Approved Manufacturing Locations
105
European Directive Information
105
Hazardous Locations Certifications (KL Option Only)
106
International Certifications
106
North American Certifications
106
European Certifications
107
Power Supply/Charger Certification
108
Label Drawings
108
Approval Drawings
111
APPENDIX C Graphics Information
115
Overview
115
Screen Layout
116
Buttons
117
Graphics Options
118
Images
118
Charts
119
Gauge Charts
123
Graphs
124
Glossary
125
Index
133
Emerson Rosemount 375 User Manual (138 pages)
Field Communicator
Brand:
Emerson
| Category:
Cell Phone
| Size: 3.36 MB
Table of Contents
Table of Contents
3
Table of Contents
5
Section 1
9
Introduction
9
Using this Manual
9
Section 2
11
Learning the Basics
11
Overview
11
Safety Messages
11
Product Overview and Precautions
12
Installing the System Card and the Battery Pack
14
Starting up and Shutting down
15
Starting the 375 Field Communicator
15
Entering Stand by
16
Shutting down the 375 Field Communicator
16
Basic Features and Functions
17
Using the Keypad
18
Using the Touch Screen
20
The 375 Main Menu
21
Starting the HART Application
21
Starting the Fieldbus Application
21
Running the Settings Menu
21
Communicating with a PC
27
Using the Scratchpad Application
29
Managing Storage
33
Types of Storage
33
Maintenance
34
Battery Information
34
Running a Self Test
36
Working in an Intrinsically Safe (IS) Area
36
Calibrating
36
Waste Disposal
37
Hazardous Substances
37
Overview
39
HART Functionality
39
Section 3
39
Safety Messages
39
Basic Features and Functions
40
Using a Fast Key Sequence
40
Starting the HART Application
40
Working Offline
41
Creating New Configurations (Offline)
41
Opening Saved Configurations (Offline)
42
Working Online
46
Connecting to a HART Loop
46
Displaying the Online Menu
49
Saving an Online Configuration
50
Displaying the Device Setup Submenu
50
Displaying Graphics
52
Using Hot Keys
53
Setting up Hot Key Options
53
Executing Hot Key Options
54
Removing Hot Key Options One at a Time
54
Removing All Hot Key Options
54
Configuring the HART Application
55
Changing the HART Polling Option
55
Changing Ignored Status Messages
56
Changing the Menu Title
56
Storage Cleanup
57
Viewing Available Device Descriptions
57
Simulating an Online Connection to a HART Device
58
Running HART Diagnostics
59
DC Voltage Measurement (HART Terminals)
59
Disconnecting from a HART Device
59
Fieldbus Functionality
61
Section 4
61
Overview
61
Safety Messages
61
Basic Features and Functions
62
Link Active Scheduler (LAS)
62
Device Interoperability
63
LAS Hierarchy
63
St_Rev
63
Starting the Fieldbus Application
64
Working Online
65
Connecting to a Fieldbus Loop
65
Displaying the Live Device List
69
Displaying the Block List
70
Modes
71
Working with Device Blocks
74
Other Block List Selections
76
Displaying Graphics
80
Configuring the Fieldbus Application
81
Changing the Fieldbus Polling Addresses
81
Changing the Slot Time
81
Viewing Available Device Descriptions
82
Running Fieldbus Diagnostics
83
DC Voltage and Noise Level Measurement
83
Signal Level Measurement
83
Disconnecting from Afieldbus Device
84
Section 5
85
Troubleshooting Suggestions
85
Overview
85
Error and Status Messages
90
Required Information for Technical Assistance
94
APPENDIX A Reference Information
95
Processor and Memory Specifications
95
Microprocessor
95
Memory
95
Physical Specifications
95
Weight
95
Display
95
Keypad
96
Power Supply Specifications
96
Connection Specifications
97
Environmental Specifications
97
Order Information
98
Spare Parts List
99
APPENDIX B Product Certifications
101
Overview
101
Approved Manufacturing Locations
101
European Directive Information
101
Hazardous Locations Certifications (KL Option Only)
102
North American Certifications
102
European Certifications
103
Charger / Power Supply Certification
104
Label Drawings
104
Approval Drawings
107
APPENDIX C Graphics Information
111
Overview
111
Screen Layout
112
Buttons
113
Graphics Options
114
Images
114
Charts
115
Graphs
120
Glossary
121
Index
129
Advertisement
Emerson Rosemount 375 User Manual (138 pages)
Field Communicator
Brand:
Emerson
| Category:
Cell Phone
| Size: 3.45 MB
Table of Contents
Table of Contents
3
Table of Contents
5
Section 1
9
Introduction
9
Using this Manual
9
Section 2
11
Learning the Basics
11
Overview
11
Safety Messages
11
Product Overview and Precautions
12
Installing the System Card and the Battery Pack
14
Starting up and Shutting down
15
Starting the 375 Field Communicator
15
Entering Stand by
16
Shutting down the 375 Field Communicator
16
Basic Features and Functions
17
Using the Keypad
18
Using the Touch Screen
20
The 375 Main Menu
21
Starting the HART Application
21
Starting the Fieldbus Application
21
Running the Settings Menu
21
Communicating with a PC
27
Using the Scratchpad Application
29
Managing Storage
33
Types of Storage
33
Maintenance
34
Battery Information
34
Running a Self Test
36
Working in an Intrinsically Safe (IS) Area
36
Calibrating
36
Waste Disposal
37
Hazardous Substances
37
Overview
39
HART Functionality
39
Section 3
39
Safety Messages
39
Basic Features and Functions
40
Using a Fast Key Sequence
40
Starting the HART Application
40
Working Offline
41
Creating New Configurations (Offline)
41
Opening Saved Configurations (Offline)
42
Working Online
46
Connecting to a HART Loop
46
Displaying the Online Menu
49
Saving an Online Configuration
50
Displaying the Device Setup Submenu
50
Displaying Graphics
52
Using Hot Keys
53
Setting up Hot Key Options
53
Executing Hot Key Options
54
Removing Hot Key Options One at a Time
54
Removing All Hot Key Options
54
Configuring the HART Application
55
Changing the HART Polling Option
55
Changing Ignored Status Messages
56
Changing the Menu Title
56
Storage Cleanup
57
Viewing Available Device Descriptions
57
Simulating an Online Connection to a HART Device
58
Running HART Diagnostics
59
DC Voltage Measurement (HART Terminals)
59
Disconnecting from a HART Device
59
Fieldbus Functionality
61
Section 4
61
Overview
61
Safety Messages
61
Basic Features and Functions
62
Link Active Scheduler (LAS)
62
Device Interoperability
63
LAS Hierarchy
63
St_Rev
63
Starting the Fieldbus Application
64
Working Online
65
Connecting to a Fieldbus Loop
65
Displaying the Live Device List
69
Displaying the Block List
70
Modes
71
Working with Device Blocks
74
Other Block List Selections
76
Displaying Graphics
80
Configuring the Fieldbus Application
81
Changing the Fieldbus Polling Addresses
81
Changing the Slot Time
81
Viewing Available Device Descriptions
82
Running Fieldbus Diagnostics
83
DC Voltage and Noise Level Measurement
83
Signal Level Measurement
83
Disconnecting from Afieldbus Device
84
Section 5
85
Troubleshooting Suggestions
85
Overview
85
Error and Status Messages
90
Required Information for Technical Assistance
94
APPENDIX A Reference Information
95
Processor and Memory Specifications
95
Microprocessor
95
Memory
95
Physical Specifications
95
Weight
95
Display
95
Keypad
96
Power Supply Specifications
96
Connection Specifications
97
Environmental Specifications
97
Order Information
98
Spare Parts List
99
APPENDIX B Product Certifications
101
Overview
101
Approved Manufacturing Locations
101
European Directive Information
101
Hazardous Locations Certifications (KL Option Only)
102
North American Certifications
102
European Certifications
103
Charger / Power Supply Certification
104
Label Drawings
104
Approval Drawings
107
APPENDIX C Graphics Information
111
Overview
111
Screen Layout
112
Buttons
113
Graphics Options
114
Images
114
Charts
115
Graphs
120
Glossary
121
Index
129
Emerson Rosemount 375 Getting Started (13 pages)
Field Communicator w/ Foundation Fieldbus & HART
Brand:
Emerson
| Category:
Cell Phone
| Size: 0.41 MB
Table of Contents
Important Notice
3
Product Overview and Precautions
4
Charging the Battery
6
Installing the System
7
Card and Battery
7
System Card
8
Communication Terminals
8
Technical Support
8
Maintenance , Repair , and Troubleshooting
9
Waste Disposal
9
Hazardous Substances
9
Product Certifications
10
Emerson Rosemount 375 Upgrade Procedures (12 pages)
Field Communicator
Brand:
Emerson
| Category:
Cell Phone
| Size: 0.37 MB
Table of Contents
Instructions for Upgrading Easy Upgrade to Version 3.X
2
Overview
2
Upgrade Procedure
2
Prerequisites
3
Download the New Easy Upgrade Utility Version 3.X
3
Download New Version 3.X System Software and Dds to PC
4
Upgrade the System Card
5
Upgrade the Field Communicator
9
Register the Field Communicator
10
Troubleshooting Tips
11
Advertisement
Related Products
Emerson Micro Motion 3750
Emerson Micro Motion 3700
Emerson Fisher 3710
Emerson Fisher 3720
Emerson Fisher 3722
Emerson Fisher 377
Emerson Rosemount 370XA
Emerson Rosemount 372
Emerson 378254
Emerson Micro Motion 3711
Emerson Categories
Controller
Control Unit
Transmitter
Measuring Instruments
Fan
More Emerson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL