Sign In
Upload
Manuals
Brands
ADC Manuals
Network Hardware
HiGain H2TU-C-231
ADC HiGain H2TU-C-231 Manuals
Manuals and User Guides for ADC HiGain H2TU-C-231. We have
10
ADC HiGain H2TU-C-231 manuals available for free PDF download: Manual, User Manual, Quick Installation
ADC HiGain H2TU-C-231 User Manual (74 pages)
ADC H2TU-C-231 List 2 Line Unit
Brand:
ADC
| Category:
Network Hardware
| Size: 1.34 MB
Table of Contents
Table of Contents
5
LTPH-UM-1109-01, Issue
9
Overview
9
Features
9
H2TU-C-231 List
10
Compatibility
10
Applications
10
Front Panel
11
H2TU-C-231 List 2 Front Panel
11
Front-Panel Description
12
Front-Panel Display Messages
13
Installation
15
Installing the H2TU-C-231 List 2 into a Shelf
15
Verification
16
Verification Without an H2TU-R Remote Unit
16
Verification with an H2TU-R Remote Unit
16
January
17
Provisioning
17
Using the MODE and SEL Pushbuttons
17
Setting Options through MODE and SEL
17
Resetting to Factory Default Values
18
Displaying System Parameter Settings
18
Disabling an Alarm
18
Loopback Modes
18
Using a Maintenance Terminal
19
Connecting to a Maintenance Terminal
19
Logon Screen
19
Navigational Keys for the Maintenance Terminal Screens
19
Logon Screen Menus
20
Provisioning Tasks
21
Setting Date and Time
21
Config Menu - Date and Time
21
Setting Circuit ID Numbers
22
Inventory Screen
22
Configuring the System
23
Config Menu
23
Config Menu - Standard Options (Defaults Shown)
24
Config Menu - ADC Options (Defaults Shown)
24
H2TU-C-231 List 2 Standard Config Menu Options
25
H2TU-C-231 List 2 ADC Config Menu Options
26
DS1/DSX-1 24-Hour PM Threshold
29
Config Menu - Set Factory Defaults
30
Clearing the History, Alarm, and Event Log Screens
31
Config Menu - Master Clear
31
Monitoring System Activity and Performance
32
Using the Monitor Screen to View System Activity
32
Monitor Screen - Active Loopback with Alarms
32
Monitor Screen Descriptions
33
Using the Performance Screens to View Performance Data
34
Performance History at the DS1 Interface
34
H2TU-R DS1 31-Day Performance History
34
H2TU-C DS1 48-Hour Performance History
35
H2TU-R DS1 25-Hour Performance History
35
H2TU-R DS1 Current Statistics
36
H2TU-C DS1 Current Statistics
36
Acronyms Used on the DS1 Performance History Screens
37
Performance History at the HDSL2 Interface
38
H2TU-C HDSL2 31-Day Performance History
38
H2TU-C HDSL2 48-Hour Performance History
38
H2TU-C HDSL2 25-Hour Performance History
39
H2TU-C HDSL2 Current Statistics
39
Using the Performance Screens to View Alarm Data
40
Acronyms Used on the HDSL2 Performance History Screens
40
Alarm History at the DS1 Interface
41
H2TU-C DS1 Alarm History Screen
41
H2TU-R DS1 Alarm History Screen
41
DS1 Alarm Descriptions
42
Alarm History at the HDSL2 Interface
43
H2TU-C HDSL2 Alarm History Screen
43
HDSL2 Alarm Descriptions
43
Using the System Event Log to Track Events
44
Using the Report Menu
45
Report Types
46
Event Log Entry Messages List
47
Testing
48
System Alarms
48
Alarm Option for Digital Loop Carrier (DLC) Feed
49
Retiring System Alarms
49
Remote LOS and AIS Response
50
OCT55 Test Pattern with AMI Line Code
50
H2TU-R LOS and AIS Response Priorities
50
Loopback Operation
51
Generic Loopback Commands
51
Loopback Summary
51
Summary of Higain HDSL2 Loopback Codes and Activation Methods
52
Special Loopback Commands
53
Manual Loopback Session
54
Loopback Test Procedures
55
General Troubleshooting Tips
55
GNLB Test Procedures
55
Loopback Modes
56
A1LB, A2LB, and A5LB Test Procedures
57
Addressable Repeater Loopback Commands (A1LB, A2LB, A5LB)
57
A3LB and A4LB Test Procedures
59
Addressable Repeater Loopback Commands (A3LB and A4LB)
59
Testing with H2TU-C BERT Generator
60
H2TU-C BERT Generator Screen
60
BERT Signal Generator Option Settings
60
Testing with H2TU-R BERT Generator
61
Appendix A - Specifications
62
Power Consumption
63
Maximum Power Dissipation
63
Maximum Current Drain
63
H2TU-C-231 Power Parameters
63
Loop Attenuation, Insertion Loss, and Reach
64
HDSL2 Reach Chart
64
H2TU-C-231 List 2 Card-Edge Connector
65
Network Management Control Bus
65
Fuse Alarm
66
System Alarm Output Pins
66
Craft Port
66
Appendix B - Functional Operation
67
Timing
67
Ground Fault Detect
67
H2TU-C-231 List 2 Block Diagram
67
Appendixc - Compatibility
68
Appendix C - Compatibility ____________________________________________________________ 60
69
Appendix D - Product Support
69
Appendix E - Abbreviations
70
Certification and Warranty
73
Advertisement
ADC HiGain H2TU-C-231 Manual (81 pages)
Brand:
ADC
| Category:
Network Hardware
| Size: 1.5 MB
Table of Contents
Table of Contents
5
Overview
11
Features
11
Compatibility
12
Applications
12
Higain Regenerators
13
Front Panel
14
H2TU-C-231 List 1E Front Panel
14
Front-Panel Display Messages
16
Installation
19
Verification
20
Verification Without a Downstream Device
20
Verification with a Downstream Device
20
Provisioning Requirements
21
Provisioning
22
Using the MODE and SEL Buttons
22
Setting Options through MODE and SEL
22
Resetting to Factory Default Values
23
Displaying System Parameter Settings
23
Disabling an Alarm
23
Loopback Modes
23
Using a Maintenance Terminal
24
Connecting to a Maintenance Terminal
24
The Logon Screen
24
Logon Screen
25
Logon Screen Menus
25
Provisioning Tasks
26
Setting Date and Time
26
Configuration Menu - Date and Time
26
Setting Circuit ID Numbers
27
Making Changes to the System Configuration
28
Configuration Menu
28
Configuration Menu - Standard Options (Defaults Shown)
29
Configuration Menu - Pairgain Options (Defaults Shown)
29
H2TU-C-231 List 1E Standard Config Screen Options
30
H2TU-C-231 List 1E Pairgain Config Screen Options
31
Extended Superframe Format
35
Higain HDSL2 Loopback Vs. Latching Sequence
37
Configuration Menu - Reset to Factory Defaults
39
Clearing the History, Alarm, and Event Log Screens
40
Master Clear
40
Monitoring System Activity and Performance
41
System Overview
41
System Spans
41
Using the Monitor Screen to View System Activity
42
Using the Performance Screens to View Performance Data
44
Performance History at the DS1 Interface
45
H2TU-C DS1 25-Hour Performance History
45
Performance History at the HDSL2 Interface
47
H2TU-C HDSL2 31-Day Performance History
47
Current Statistics Screens for the DS1 Interface
48
H2TU-R DS1 Current Statistics
48
H2TU-C DS1 Current Statistics
48
Current Statistics for HDSL2 Interface
49
H2TU-C HDSL2 Current Statistics
49
Using the Performance Screens to View Alarm Data
50
Alarm History at the DS1 Interface
50
H2TU-C DS1 Alarm History Screen
50
H2TU-R DS1 Alarm History Screen
51
Alarm History at the HDSL2 Interface
52
H2TU-C HDSL2 Alarm History Screen
52
Using the Event Log to Track System Events
53
System Event Log
53
Testing
55
Front-Panel System Alarms
55
Front-Panel System Alarms Summary
55
Alarm Option for Digital Loop Carrier (DLC) Feed
56
Retiring System Alarms
56
Remote LOS and AIS Response
57
OCT55 Test Pattern with AMI Code
57
Loopback Operation
58
Generic Loopback Commands
58
Special Loopback Commands
60
Manual Loopback Session
61
Loopback Test Procedures
62
General Troubleshooting Tips
62
GNLB Test Procedures
62
Loopback Modes
63
A2LB Test Procedures
64
Addressable Repeater Loopback Commands (A2LB)
64
A3LB and A4LB Test Procedures
67
Addressable Repeater Loopback Commands (A3LB and A4LB)
67
Appendix A - Specifications
68
Power Consumption
69
Maximum Power Dissipation
69
Maximum Current Drain
69
H2TU-C-231 List 1E Card Connector
70
Network Management Control Bus
70
H2TU-C-231 List 1E Card-Edge Connector
70
Fuse Alarm
71
System Alarm Output Pins
71
Craft Port
71
RS-232 Craft Port Pinouts
71
Appendix B - Functional Operation
72
H2TU-C-231 List 1E Block Diagram
72
Timing
73
Ground Fault Detect
73
Appendixc - Compatibility
74
Appendix D - Product Support
75
Appendix E - Abbreviations
77
Certification and Warranty
79
Limited Warranty
79
ADC HiGain H2TU-C-231 User Manual (66 pages)
ADC H2TU-C-388 List 1 Line Unit User Manual
Brand:
ADC
| Category:
Network Hardware
| Size: 0.91 MB
Table of Contents
Table of Contents
5
H2TU-C-388 List
9
Overview
9
Features
9
Issue
10
Compatibility
10
Applications
10
Front Panel
11
H2TU-C-388 List 1 Front Panel
11
Front-Panel Description
12
Front-Panel Display Messages
13
June
14
Installation
15
Installing the H2TU-C-388 into a Shelf
15
Verification
16
Verification Without a Downstream Device
16
Verification with a Downstream Device
16
Provisioning
17
Using the MODE and SEL Buttons
17
Setting Options through MODE and SEL
17
Resetting to Factory Default Values
18
Displaying System Parameter Settings
18
Loopback Modes
18
Using a Maintenance Terminal
18
Connecting to a Maintenance Terminal
18
The Logon Screen
19
Navigational Keys for the Higain Maintenance Terminal Screens
19
Logon Screen
20
Logon Screen Menus
20
Provisioning Tasks
21
Setting Date and Time
21
Configuration Menu - Date and Time
21
Setting Circuit ID Numbers
22
Inventory Menu
22
Configuring the System
23
Configuration Menu
23
Configuration Menu - Standard Options (Defaults Shown)
24
Configuration Menu - ADC Options (Defaults Shown)
24
Higain Line Unit List 1 Standard Config Screen Options
25
Higain Line Unit List 1 ADC Config Screen Options
26
Configuration Menu - Reset to Factory Defaults
28
DS1/DSX-1 24-Hour PM Threshold
28
Clearing the History, Alarm, and Event Log Screens
29
Master Clear
29
Monitoring System Activity and Performance
30
Using the Monitor Screen to View System Activity
30
Monitor Screen - Active Loopback with Alarms
30
Monitor Screen Descriptions
31
Using the Performance Screens to View Performance Data
32
Performance History at the DS1 Interface
32
H2TU-R DS1 31-Day Performance History
32
H2TU-R DS1 48-Hour Performance History
33
H2TU-C DS1 25-Hour Performance History
33
H2TU-R DS1 Current Statistics
34
H2TU-C DS1 Current Statistics
34
Acronyms Used on the DS1 Performance History Screens
35
Performance History at the HDSL2 Interface
36
H2TU-C HDSL2 31-Day Performance History
36
H2TU-C HDSL2 48-Hour Performance History
36
H2TU-C HDSL2 25-Hour Performance History
37
H2TU-C HDSL2 Current Statistics
37
Using the Performance Screens to View Alarm Data
38
Acronyms Used on the HDSL2 Performance History Screens
38
Alarm History at the DS1 Interface
39
H2TU-C DS1 Alarm History Screen
39
H2TU-R DS1 Alarm History Screen
39
DS1 Alarm Descriptions
40
Alarm History at the HDSL2 Interface
41
H2TU-C HDSL2 Alarm History Screen
41
HDSL2 Alarm Descriptions
41
Using the Event Log to Track System Events
42
Event Log Entry Messages List
43
Testing
44
Front-Panel System Alarms
44
Front-Panel System Alarms Summary
44
Alarm Option for DLC Feed
45
Retiring System Alarms
45
Remote LOS and AIS Response
46
OCT55 Test Pattern with AMI Line Code
46
H2TU-R LOS and AIS Response Priorities
46
Loopback Operation
47
Generic Loopback Commands
47
Loopback Summary
47
Summary of Higain Loopback Codes and Activation Methods
48
Special Loopback Commands
49
Manual Loopback Session
50
Loopback Test Procedures
51
General Troubleshooting Tips
51
GNLB Test Procedures
51
Loopback Modes
52
A1LB, A2LB, and A5LB Test Procedures
53
Addressable Repeater Loopback Commands (A1LB, A2LB, A5LB)
53
A3LB and A4LB Test Procedures
55
Addressable Repeater Loopback Commands (A3LB and A4LB)
55
Appendix A - Specifications
56
Power Consumption
57
Maximum Power Dissipation
57
Maximum Current Drain
57
H2TU-C-388 Power Parameters
57
Loop Attenuation
58
Higain Line Unit Card-Edge Connector
58
Network Management Control Bus
58
HDSL2 Cable Attenuation Chart
58
Fuse Alarm
59
Craft Port
59
To-DB-9 Adapter
59
Appendix B - Functional Operation
60
Timing
60
Ground Fault Detect
60
H2TU-C-388 List 1 Block Diagram
60
Appendixc - Compatibility
61
Appendix C - Compatibility ____________________________________________________________ 53
62
Appendix D - Product Support
62
Appendix E - Abbreviations
63
Certification and Warranty
65
Advertisement
ADC HiGain H2TU-C-231 User Manual (80 pages)
Line Unit
Brand:
ADC
| Category:
Network Hardware
| Size: 1.1 MB
Table of Contents
Table of Contents
5
Overview
9
Features
9
Applications
10
Front Panel
11
H2TU-C-231 List 3F Front Panel
11
Front-Panel Display Messages
13
Installation
15
Verification
16
Verification Without an H2TU-R Remote Unit
16
Verification with an H2TU-R Remote Unit
16
Provisioning
17
Displaying System Parameter Settings
17
Accessing the Provisioning Screens
17
Connecting to a Maintenance Terminal
17
Logon Screen
18
Provisioning Tasks
20
Setting Date and Time
20
Config Menu
20
Setting Circuit ID Numbers
21
Configuring the System
22
H2TU-C-231 List 3F Standard Config Menu Options
24
H2TU-C-231 List 3F ADC Config Menu Options
25
Extended Superframe Format
29
Resetting to Factory Defaults
32
Clearing the History, Alarm, and Event Log Screens
33
Monitoring System Activity and Performance
34
Performance Monitoring from the H2TU-R
34
Sectionalized Analysis of the DS1 Interface
34
Payload Retrieval of Margin and Pulse Attenuation Parameters
35
Using the Monitor Screen to View System Activity
36
Using the Performance Screens to View Performance Data
38
Performance History at the DS1 Interface
38
H2TU-C DS1 Current Statistics
41
Blockage Indicator Statistics at the H2TU-R DS1 Interface
42
Performance History at the HDSL2 Interface
43
H2TU-C HDSL2 31-Day Performance History
43
H2TU-C HDSL2 48-Hour Performance History
43
H2TU-C HDSL2 25-Hour Performance History
44
H2TU-C HDSL2 Current Statistics
44
Using the Performance Screens to View Alarm Data
45
Alarm History at the DS1 Interface
45
H2TU-C DS1 Alarm History Screen
46
H2TU-R DS1 Alarm History Screen
46
Alarm History at the HDSL2 Interface
48
H2TU-C HDSL2 Alarm History Screen
48
Using the System Event Log to Track Events
49
System Event Log
49
Origin Tags
49
Event Log Messages
50
Origin Tags
51
Using the Sectionalized Event Log to Isolate Trouble
52
Sectionalized Event Log Screen
52
Sectionalized Analysis of the DS1 Interface
53
Sectionalized Event Definitions
53
Using the Report Menu
54
Report Types
55
Testing
56
System Alarms
56
Front-Panel System Alarms Summary
56
Alarm Option for the Digital Loop Carrier Feed
57
Retiring System Alarms
57
Remote LOS and AIS Response
58
OCT55 Test Pattern with AMI Line Code
58
Loopback Operation
59
Addressable Repeater Loopback Commands: A1LB, A2LB, A5LB
59
Generic Loopback Commands
60
Special Loopback Commands
61
Manual Loopback Session
62
Setting the Loopback Time-Out Option
62
Activating Manual Loopback Mode
62
Loopback Test Procedures
63
General Troubleshooting Tips
63
GNLB Test Procedures
63
A1LB, A2LB, and A5LB Test Procedures
64
Loopback Modes
64
A3LB and A4LB Test Procedures
67
Testing with the H2TU-R Signal Generator
68
Signal Generator Option Settings
68
Appendix A - Specifications
69
Power Consumption
70
Maximum Power Dissipation
70
Maximum Current Drain
70
H2TU-C-231 List 3F Power Parameters
70
Loop Attenuation
71
H2TU-C-231 List 3F Card-Edge Connector
71
Network Management Control Bus
72
Fuse Alarm
72
System Alarm Output Pin
72
Craft Port
73
RS-232 Craft Port Pinouts
73
Appendix B - Functional Operation
74
Timing
74
Ground Fault Detect
74
H2TU-C-231 List 3F Block Diagram
74
Appendixc - Compatibility
75
Appendix D - Product Support
76
Appendix E - Abbreviations
77
Certification and Warranty
79
ADC HiGain H2TU-C-231 Manual (76 pages)
Brand:
ADC
| Category:
Network Hardware
| Size: 1.32 MB
Table of Contents
Table of Contents
5
Overview
9
Features
9
Compatibility
10
Applications
10
Front Panel
11
H2TU-C-231 List 4E Front Panel
11
Front-Panel Display Messages
13
Installation
15
Verification
16
Verification Without an H2TU-R Remote Unit
16
Verification with an H2TU-R Remote Unit
16
Provisioning
17
Using the MODE and SEL Pushbuttons
17
Setting Options through MODE and SEL
17
Resetting to Factory Defaults
18
Displaying System Parameter Settings
18
Disabling an Alarm
18
Loopback Modes
18
Using a Maintenance Terminal
18
Connecting to a Maintenance Terminal
18
Logon Screen
19
Logon Screen
20
Provisioning Tasks
21
Setting Date and Time
21
Config Menu
21
Setting Circuit ID Numbers
22
Configuring the System
23
H2TU-C-231 List 4E Standard Config Menu Options
25
H2TU-C-231 List 4E ADC Config Menu Options
26
Extended Superframe Format
31
Higain HDSL2 Loopback Vs. Latching Sequence
33
Clearing the History, Alarm, and Event Log Screens
34
Monitoring System Activity and Performance
36
Using the Monitor Screen to View System Activity
36
Using the Performance Screens to View Performance Data
38
Performance History at the DS1 Interface
38
H2TU-R DS1 Current Statistics
40
H2TU-C DS1 Current Statistics
40
Performance History at the HDSL2 Interface
42
H2TU-C HDSL2 31-Day Performance History
42
H2TU-C HDSL2 48-Hour Performance History
42
H2TU-C HDSL2 25-Hour Performance History
43
H2TU-C HDSL2 Current Statistics
43
Using the Performance Screens to View Alarm Data
44
Alarm History at the DS1 Interface
44
H2TU-C DS1 Alarm History Screen
45
H2TU-R DS1 Alarm History Screen
45
Alarm History at the HDSL2 Interface
47
H2TU-C HDSL2 Alarm History Screen
47
Using the System Event Log to Track Events
48
System Event Log
48
Using the Report Menu
50
Report Types
51
Testing
52
System Alarms
52
Front-Panel System Alarms Summary
52
Alarm Option for Digital Loop Carrier (DLC) Feed
53
Retiring System Alarms
53
Remote LOS and AIS Response
54
OCT55 Test Pattern with AMI Code
54
Loopback Operation
55
Addressable Repeater Loopback Commands: A2LB
55
Generic Loopback Commands
56
Special Loopback Commands
56
Smartjack Loopback Commands
57
Manual Loopback Session
57
In-Band Loopback Sessions
58
General Troubleshooting Tips
58
GNLB Test Procedures
58
Loopback Modes
59
A2LB Test Procedures
60
A3LB and A4LB Test Procedures
62
Smartjack Test Procedure
62
Smartjack Loopup and Loopdown Commands
62
Appendix A - Specifications
63
Power Consumption
64
Maximum Power Dissipation
64
Maximum Current Drain
64
Loop Attenuation
65
H2TU-C-231 List 4E Card-Edge Connector
66
Network Management Control Bus
66
Fuse Alarm
67
System Alarm Output Pins
67
Craft Port
67
RS-232 Craft Port Pinouts
67
Appendix B - Functional Operation
68
H2TU-C-231 List 4E Block Diagram
68
Timing
69
Ground Fault Detect
69
Appendix C - Compatibility
70
Appendixd - Product Support
71
Technical Support
71
Returns
71
Appendix E - Abbreviations
72
Certification and Warranty
75
ADC HiGain H2TU-C-231 Quick Installation (7 pages)
Brand:
ADC
| Category:
Network Hardware
| Size: 0.76 MB
Table of Contents
Specifications
2
Installation
3
Power-Up Sequence
3
Loopback Testing
6
ADC HiGain H2TU-C-231 Quick Installation (7 pages)
Line unit
Brand:
ADC
| Category:
Network Hardware
| Size: 0.29 MB
Table of Contents
Specifications
2
Installation
3
Power-Up Sequence
3
Loopback Testing
5
ADC HiGain H2TU-C-231 Quick Installation (7 pages)
Line Unit
Brand:
ADC
| Category:
Network Hardware
| Size: 0.29 MB
Table of Contents
Specifications
2
Installation
3
Power-Up Sequence
3
Loopback Testing
5
ADC HiGain H2TU-C-231 Quick Installation (7 pages)
Line Unit
Brand:
ADC
| Category:
Network Hardware
| Size: 2.02 MB
ADC HiGain H2TU-C-231 Quick Installation (2 pages)
Line Unit
Brand:
ADC
| Category:
Network Hardware
| Size: 0.25 MB
Advertisement
Related Products
ADC HiGain H2TU-C-319 List 4E
ADC H2TU-C-388 HiGain
ADC H2TU-C-231-L2
ADC H2TU-C-L4E
ADC H2TU-R-402 List 4E
ADC H2TU-C-231-L3F
ADC HiGain HDSL2
ADC HRE-602 List 1
ADC HRE-602 List 1B
ADC H4TU-C-388-L1
ADC Categories
Network Hardware
Dryer
Medical Equipment
Thermometer
Blood Pressure Monitor
More ADC Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL