MH-C9000
WizardOne Charger-Analyzer
Thank you for purchasing the Powerex MH-C9000
Charger-Analyzer. Read these instructions carefully
and thoroughly before operating this unit. IMPORTANT
SAFETY INSTRUCTIONS. READ AND SAVE THESE
INSTRUCTIONS.
OPERATING THIS PRODUCT INCORRECTLY CAN
CAUSE DAMAGE TO THE BATTERIES.
READ MANUAL COMPLETELY BEFORE USE.
GENERAL PRECAUTIONS
Do not charge battery cells other than NiMH or NiCD. Please check
•
with the battery manufacturer to ensure it can accept the
programmed charging and discharging rates. Do not expose the unit
to rain or moisture due to the risk of fire.
Do not operate the charger if it appears damaged in any way.
•
Always place the battery cells with positive tip facing the top.
•
Incorrect polarity may cause fire or explosion. Observe polarity
diagrams located on the charger.
Do not allow the unit to be exposed to direct sunlight. Operate in
•
well-ventilated area. Do not place unit on the carpet.
Do not allow the battery terminals to become shorted.
•
To reduce the risk of damage to the power cord, always pull by
•
connector rather than the cord.
Use only the supplied adapter or optional regional and car adapter
•
offered by Maha Energy. Using third party accessories voids the
product warranty.
FEATURES & SPECIFICATIONS
Four independent slots for AA or AAA NiMH batteries.
•
Backlit LCD display.
•
Digitally displays capacity, voltage, time and current.
•
Five modes of operation: Charge, Refresh & Analyze, Break-In,
•
Discharge and Cycle.
19 selectable charging current from 0.2A to 2.0A.
•
10 selectable discharging current from 0.1A to 1.0A.
•
Worldwide power supply.
•
Charging Current:
Programmable from 0.2A to 2.0A in
increments of 0.1A
Topoff Charging Current:
100mA
Maintenance Charging
10mA
Current:
Discharge Termination:
Voltage 1.00V
Discharging Current:
Programmable from 0.1A to 1.0A in
increments of 0.1A
Capacity Storage Memory:
12 (Cycle mode only)