Omron BP653 Instruction Manual

Omron BP653 Instruction Manual

Wrist blood pressure monitor

Advertisement

INSTRUCTION MANUAL
Wrist Blood
Pressure Monitor
Model BP653

Advertisement

Table of Contents
loading

Summary of Contents for Omron BP653

  • Page 1 INSTRUCTION MANUAL Wrist Blood Pressure Monitor Model BP653...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Before using the Monitor Introduction ......................3 Safety information ....................4 Intended use....................4 General usage ..................4 Battery usage ..................5 Data transmission ...................5 General usage ..................5 Battery usage ..................5 General precautions................6 Operating Instructions Before taking a measurement ..................7 Know your unit......................8 Unit display ......................9 Display symbols ....................10 Heartbeat symbol..................10...
  • Page 3: Introduction

    INTRODUCTION Thank you for purchasing the OMRON BP653 Wrist Blood Pressure Monitor. Fill in for future reference. DATE PURCHASED: __________________ SERIAL NUMBER: ____________________ • Staple your purchase receipt here • Register your product on-line at www.register-omron.com The monitor is compact and easy-to-use at home, at work, and portable for travel.
  • Page 4: Safety Information

    SAFETY INFORMATION INTENDED USE The device is a digital monitor intended for use in measuring blood pressure and pulse rate in adult patient population with wrist circumference ranging from 5 1/4 inches to 8 1/2 inches (13.5 cm to 21.5 cm). The device detects the appearance of irregular heartbeats during measurement and gives a warning signal with readings.
  • Page 5: Battery Usage

    Do not use the device in a moving vehicle (car, airplane). Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit. Although this device is waterproof (IP22), please be careful about the operating environment.
  • Page 6: General Precautions

    SAFETY INFORMATION GENERAL PRECAUTIONS Do not subject the monitor to strong shocks, such as dropping the unit on the floor. Do not submerge the device or any of the components in water. Store the device and the components in a clean, safe location. Changes or modification not approved by the manufacturer will void the user warranty.
  • Page 7: Before Taking A Measurement

    BEFORE TAKING A MEASUREMENT To ensure a reliable reading, follow these recommendations: 1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 5 minutes before taking the measurement. 2. Stress raises blood pressure. Avoid taking measurements during stressful times. 3.
  • Page 8: Know Your Unit

    STARTED Model BP653 5371250-3A Wrist Blood Pressure Monitor INTRODUCTION Thank you for purchasing the OMRON BP653 Wrist Blood Pressure Monitor. Fill in for future reference. DATE PURCHASED: __________________ SERIAL NUMBER: ____________________ BP653 • Staple your purchase receipt here • Register your product on-line at...
  • Page 9: Unit Display

    UNIT DISPLAY Average reading symbol Memory symbol Date/Time display USER ID symbol Blood pressure level Systolic blood indicator (High/Normal) pressure Positioning indicator Diastolic blood pressure Positioning symbol Battery symbol (low/depleted) Movement error symbol Heartbeat symbol Irregular heartbeat symbol (Flashes during Blood pressure level indicator (bar) measurement) Deflation symbol...
  • Page 10: Display Symbols

    DISPLAY SYMBOLS HEARTBEAT SYMBOL ( The Heartbeat symbol flashes on the display at every heartbeat during the measurement. AVERAGE READING SYMBOL ( The Average Reading Symbol is displayed when you press and hold the button for more than 2 seconds. The most recent average reading appears on the display screen. IRREGULAR HEARTBEAT SYMBOL ( When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol will appear on the display with the...
  • Page 11 DISPLAY SYMBOLS 2013 ESH/ESC Guidelines for the management of arterial hypertension Definitions of hypertension by office and home blood pressure levels Office Home Systolic Blood Pressure ≥ 140 mmHg ≥ 135 mmHg Diastolic Blood Pressure ≥ 90 mmHg ≥ 85 mmHg...
  • Page 12: Battery Installation

    BATTERY INSTALLATION 1. Push down the hook of the battery cover and pull downward. 2. Install 2 “AAA” size batteries so the + (positive) and - (negative) polarities match the polarities of the battery compartment as indicated. 3. Replace the battery cover. NOTE: Make sure that the battery cover is securely in position.
  • Page 13 BATTERY INSTALLATION NOTES: • When the depleted battery symbol ( ) appears on the display, turn the monitor off and remove all the batteries. Replace with 2 new batteries at the same time. • Turn the unit off before replacing the batteries. If the batteries are removed while the unit is still on, the date and time will be reset to that of the previous use.
  • Page 14: Setting The Date And Time

    • The date and time can be automatically set when you transfer your readings to the Omron Wellness App. However, the date and time will only be set for future measurements taken after the reading that was transferred, it will not be saved to the reading that was just transferred.
  • Page 15: Applying The Wrist Cuff

    APPLYING THE WRIST CUFF APPLYING THE CUFF ON THE LEFT WRIST 1. Roll up sleeve. Make sure your sleeve is not rolled up too tightly on your arm. This may constrict the flow of blood in your arm. 2. Put your arm through the cuff loop. Your palm should face upward.
  • Page 16: Applying The Cuff On The Right Wrist

    APPLYING THE WRIST CUFF NOTES: • Make sure the wrist cuff does not cover the protruding part of the wrist bone on the outside of the wrist. • If the wrist cuff comes off, re-assemble as shown in the figure. APPLYING THE CUFF ON THE RIGHT WRIST When taking a measurement using the right wrist position the cuff as shown in the illustration.
  • Page 17: Taking A Measurement

    TAKING A MEASUREMENT The monitor is designed to store the blood pressure and the pulse rate in the memory for two people (USER 1 or 2) every time a measurement is completed. 1. Select your USER ID (1 or 2). 2.
  • Page 18 TAKING A MEASUREMENT 3. Press the START/STOP button to start the measurement. All symbols appear on the display before starting the measurement. Positioning Indicator - The monitor has a built-in positioning indicator that is used as an aid in determining if the monitor is at the correct height. It has been designed to work with most people so that when your wrist is at the correct position relative to your heart, the positioning indicator will be blue.
  • Page 19: Turn Off (On) The Positioning Indicator

    TAKING A MEASUREMENT As the cuff inflates, the monitor automatically determines your ideal inflation level. This monitor detects your blood pressure and pulse rate during inflation. The Heartbeat Symbol ( ) flashes at every heartbeat. Remain still and do not move until the entire measurement process is completed. After the monitor has detected your blood pressure and pulse rate, the cuff automatically deflates.
  • Page 20: Using The Memory Function

    USING THE MEMORY FUNCTION The monitor automatically stores up to 100 readings for each user (1 and 2). It can also calculate an average reading based on the last 3 readings taken within 10 minutes. TO VIEW THE READINGS STORED IN MEMORY 1.
  • Page 21: To Pair This Device With A Smartphone

    USING THE MEMORY FUNCTION TO PAIR THIS DEVICE WITH A SMARTPHONE To begin using the OMRON Wellness software for the first time, please visit www.omronwellness.com for the initial set-up instructions. 1. Download and install onto your smartphone, the free “Omron Wellness” App.
  • Page 22: To Transfer The Data

    Lit: 100 readings have been stored. If the memory is full, the monitor will delete the oldest reading. Please transfer your readings to the Omron Wellness App to help ensure your data is saved before old readings are deleted from the memory.
  • Page 23 USING THE MEMORY FUNCTION NOTES: • Unpairing your device will not delete the information in the mobile App. • The monitor will automatically turn off after 2 minutes. • If you re-pair your smartphone to your blood pressure monitor, all prior reading history stored on the mobile App will be retained.
  • Page 24: Care And Maintenance

    Remove the batteries if the unit will not be used for three months or longer. Always replace all the batteries with new ones at the same time. CAUTION Use only OMRON authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.
  • Page 25 CARE AND MAINTENANCE CAUTION Changes or modification not approved by the manufacturer will void the user warranty. Do not disassemble or attempt to repair the unit or components. CAUTION Do not store the device in the following situations: • If the device is wet. •...
  • Page 26: Error Messages

    ERROR MESSAGES SYMBOL CAUSE CORRECTION Please remove the wrist cuff, and wait 2-3 minutes. Reapply the wrist cuff and take another measurement. Irregular heartbeats are Repeat the steps in section “Taking a detected. Measurement”. If this error continues to appear, contact your physician.
  • Page 27 ERROR MESSAGES SYMBOL CAUSE CORRECTION Device error. Contact Customer Service. Recommend to replace the batteries Batteries are low. with new ones ahead of time. Refer to “Battery Installation”. Replace the two batteries. Batteries are depleted. Refer to “Battery Installation”.
  • Page 28: Troubleshooting Tips

    TROUBLESHOOTING TIPS PROBLEM CAUSES AND SOLUTIONS Replace both batteries with new ones at the No power. same time. Check the battery installation for No display appears on the unit. proper placement of the battery polarities. Review the section “Battery Installation”. Blood pressure varies constantly.
  • Page 29: Fcc Statement And Trademarks

    FCC STATEMENT AND TRADEMARKS FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 30 The Bluetooth Smart word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by OMRON HEALTHCARE Co.,Ltd. is under license. Other trademarks and trade names are those of their respective owners. Apple, the Apple logo, iPad, and iPhone are trademarks of Apple Inc., registered in the U.S.
  • Page 31: Limited Warranty

    LIMITED WARRANTY Your BP653 Wrist Blood Pressure Monitor, excluding the batteries, is warranted to be free from defects in materials and workmanship appearing within 5 years from the date of purchase, when used in accordance with the instructions provided with the monitor.
  • Page 32: Specifications

    SPECIFICATIONS Model: BP653 HEM-6321T-Z Display: LCD Digital Display Measurement Range: Pressure: 0 mmHg to 299 mmHg Pulse: 40 beats/min to 180 beats/min Accuracy: Pressure: ±3 mmHg or 2% of reading Pulse: ±5% of reading Inflation: Automatic by electric pump Deflation:...
  • Page 33: Guidance And Manufacturer's Declaration

    IEC60601-1-2:2007 standard for both immunity and emissions. Nevertheless, special precautions need to be observed: • The use of accessories and cables other than those specified by OMRON, with the exception of cables sold by OMRON as replacement parts for internal components, may result in increased emission or decreased immunity of the device.
  • Page 34 (Table 1) Guidance and manufacturer’s declaration – electromagnetic emissions OMRON BPM is intended for use in the electromagnetic environment specified below. The customer or the user of this OMRON BPM should assure that it is used in such environment. Electromagnetic environment...
  • Page 35 (Table 2) Guidance and manufacturer’s declaration – electromagnetic immunity OMRON BPM is intended for use in the electromagnetic environment specified below. The customer or the user of this OMRON BPM should assure that it is used in such environment. IEC 60601...
  • Page 36 GUIDANCE AND MANUFACTURER’S DECLARATION IEC 60601 Compliance Electromagnetic environment Immunity test Test level level – guidance <5 % U (>95 % dip in U for 0.5 cycle 40 % U Voltage dips, (60 % dip in short interruptions for 5 cycles and voltage Not Applicable.
  • Page 37 (Table 4) Guidance and manufacturer’s declaration – electromagnetic immunity OMRON BPM is intended for use in the electromagnetic environment specified below. The customer or the user of this OMRON BPM should assure that it is used in such environment. IEC 60601...
  • Page 38 If the measured field strength in the location in which the OMRON BPM is used exceeds the applicable RF compliance level above, the OMRON BPM should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the OMRON BPM.
  • Page 39 Recommended separation distance between portable and mobile RF communications equipment and the OMRON BPM OMRON BPM is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of this OMRON BPM can help prevent electromagnetic interference by maintaining a...
  • Page 40 Manufactured for : OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho Muko, Kyoto, 617-0002 JAPAN Distributed by : OMRON HEALTHCARE, INC. 1925 West Field Court Lake Forest, IL 60045 U.S.A. www.omronhealthcare.com © 2014 OMRON HEALTHCARE, INC. 5371250-3A Made in Vietnam...

Table of Contents