Insert Installation

Masonry Fireplace Requirements

Chimney must have a clay tile liner or a stainless steel liner (positive connection)
Entire fireplace, including chimney, must be clean and undamaged. Any damage must be repaired
prior to installation of the insert
Chimney height: 15' minimum; 33' maximum.
Entire fireplace, including chimney, must meet local building requirements
Zero-Clearance (Metal) Fireplace Requirements:
Must utilize a positive (full reline) or direct connection (block-off plate)
Must be manufactured by one of the following manufacturers:
• Marco
• Majestic
Entire fireplace, including chimney, must be clean and undamaged. Any damage must be repaired
prior to installation of the insert
Entire fireplace, including chimney, must meet local building requirements
Chimney height: 15' minimum; 33' maximum. Minimum
cross section: 28.65 square inches
The damper ("
") and grate ("
A
the illustration to the right)
The smoke shelf ("
C
and metal or glass doors ("
applicable)
The masonry lining ("
structured rigid frame members (metal sides, floor, door
frame, face of the fireplace, etc. – "
removed or altered

Drafting Performance

This appliance relies upon natural draft to operate. External forces, such as wind, barometric
pressure, topography, or factors of the home (negative pressure from exhaust fans, chimneys, air
infiltration, etc.), may adversely affect draft. Travis Industries can not be responsible for external
forces leading to less than optimal performance.

Leveling Bolt Installation

Two leveling bolts are included to level the insert if the fireplace has a stepped-up hearth. To install,
raise the rear of the insert up and insert the leveling bolts into the holes in the rear corners of the
insert. Adjust the bolts until they extend the same height as the hearth steps up. After the insert is
installed, fine-tune the leveling bolts to level the insert (see the illustration).
This distance is the
hearth step-up. The
leveling bolts should
stick out this far from the
base of the insert.
Hearth
Travis Industries
• Heatilator
• Preway
") must be removed (see
B
"), internal baffles ("
"), screen ("
D
") may be removed (if
F
"), insulation ("
"), and any
G
H
") may not be
I
Fireplace
93508131
(for qualified installers only)
• Tempco
• Superior
H
F
"),
E
E
A
C
D
I
B
G
The leveling bolts go
into the holes at the
rear corners of the
insert.
4 020327