Operating Steps - Lincoln Electric IDEALARC SP-250 Service Manual

Lincoln electric welding system user manual
Table of Contents

Advertisement

B-10

OPERATING STEPS

Before operating the machine, be sure you have all the
materials needed to perform the work. Be sure you are
familiar with and have taken all possible safety pre-
cautions before starting the work. It is important that
you follow these operating steps each time you use the
machine.
RUN-IN MODE
The IDEALARC SP-250 can operate in either a slow or
fast run-in mode. It is factory set to operate in the slow
run-in mode. In the slow run-in mode, the SP-250 ini-
tially feeds wire at the rate of 50 IPM until output cur-
rent is reached or for 2 seconds, whichever condition is
reached first.
When either of these conditions are
reached, the SP-250 accelerates to the preset wire
feed speed.
When the SP-250 is in the fast run-in mode, the wire
feed speed immediately accelerates to the preset wire
feed speed - (available on later codes only.)
CHANGING RUN-IN MODE (CODES 10001
AND ABOVE)
NOTE: Arc starting characteristics may be affected
when using the fast run-in mode because normal start-
ing processes are overridden.
1. Turn the ON/OFF POWER SWITCH to ON.
2. Press and hold both the TIMERS OFF key and the
PROCESS key.
NOTE: The order in which the TIMERS OFF key and
the PROCESS key are pressed does not matter.
3. Read the SP-250 LED display. One of two mes-
sages appear:
FAST INCH ENABLED = (Fast run-in mode)
FAST INCH DISABLED = (Slow run-in mode)
NOTE: The run-in message appears on the display for
2 seconds. Pressing the PROCESS key causes the
message to disappear immediately.
4. Select run-in mode required.
a. If run-in mode displayed is the required mode,
continue with weld process.
OPERATION
b. If run-in mode displayed is not the required
mode, repeat Step 1. By repeating Step 1, the
run-in mode changes. Pressing the TIMERS
OFF key and the PROCESS key allows you to
switch back and forth between the two run-in
modes.
You need only perform the above procedure when you
want to change the run-in mode. It is not necessary to
repeat the above procedure each time the unit is pow-
ered up. The unit will remember the run-in mode from
the previous power down and return you to that same
state on your next power up. When saving to Memory
locations 1-5, the run-in mode is saved at the same
time. All operators should be aware that when recalling
a procedure from a memory location, the run-in mode
in memory overrides any present run-in mode setting.
The run-in mode remains in effect until either the run-
in mode is changed using the double keystroke or until
a memorized procedure containing the opposite run-in
mode is recalled.
MAKING A WELD IN AUTO MODE
1. Check that the polarity is correct for the process
being used.
2. Turn the ON/OFF POWER SWITCH to ON.
3. Press (PROCESS) key.
4. Press LEFT UP or DOWN ARROW Keys to select
wire type being used.
5. Press CENTER UP or DOWN ARROW Keys to
select wire diameter being used.
6. Press RIGHT UP or DOWN ARROW Keys to
select welding gas type being used.
7. Press AUTO key. When the AUTO key is pressed,
an alarm will beep three times. The following mes-
sage is displayed for 2.5 seconds: PROCESS
MUST MATCH WIRE & GAS.
8. Press UP or DOWN ARROW Keys to select metal
thickness.
9. If SPOT or STITCH timing modes NOT required,
go to Step 12.
IDEALARC SP-250
B-10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents