D-1

SAFETY PRECAUTIONS

WARNING
Have qualified personnel do the maintenance
work. Turn the engine off before working inside
the machine. In some cases, it may be
necessary to remove safety guards to perform
required maintenance. Remove guards only
when necessary and replace them when the
maintenance requiring their removal is
complete. Always use the greatest care when
working near moving parts.
Do not put your hands near any rotating parts. If
a problem cannot be corrected by following the
instructions, take the machine to the nearest
Lincoln Field Service Shop.
-----------------------------------------------------------------------
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or
electrode with skin or wet clothing.
• Insulate yourself from work and
ground
• Always wear dry insulating gloves.
------------------------------------------------------------------------
ENGINE EXHAUST can kill.
• Use in open, well ventilated areas or
vent exhaust outside.
------------------------------------------------------------------------
MOVING PARTS can injure.
• Do not operate with enclosure or
guards off.
• Stop engine before servicing.
• Keep away from moving parts.
------------------------------------------------------------------------
See additional warning information
throughout this operator's manual and
the Engine manual as well.
-----------------------------------------------------------

MAINTENANCE

ROUTINE AND PERIODIC ENGINE
MAINTENANCE
At the end of each day's use, refill the fuel tank to min-
imize moisture condensation in the tank. Running out
of fuel tends to draw dirt into the fuel system. Also,
check the crankcase oil level and add oil if indicated.

ENGINE MAINTENANCE PARTS

Oil Filter
Air Filter
Air Filter
Pre-Cleaner
Fuel Filter
Spark Plugs
* Oil capicity increases from 2.0 Qts. to 2.1 Qts when using this filter.
RANGER 275
TABLE D.1
Kohler CH 20
Kohler 1205001
Fram PH3614*
Kohler 4708303
Fram CA79
Kohler 2408302
Kohler 2505002
Fram G1
Champion RC12YC
.030 in., (.76 mm.) gap