Welding Capability; Limitations; Controls And Settings - Lincoln Electric PRO-MIG 175 IM810 Operator's Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

B-2
G
No external shielding gas is required when used
with Lincol .035" (0.9 mm) Innershield NR
MP electrode.
G
Spindle accommodates both 8 in. (200 mm) diame-
ter and 4 in. (100 mm) diameter spools of wire.

WELDING CAPABILITY

The Pro-MIG 175 is rated at 130 amps, 20 volts, at
30% duty cycle on a ten minute basis. It is capable of
higher output currents at lower duty cycles. .

LIMITATIONS

Arc Gouging cannot be performed with the Pro-MIG
175. The Pro-MIG 175 is not recommended for pipe
thawing or TIG welding.

CONTROLS AND SETTINGS

Refer to Figure B.1a.
1. Power ON/OFF Switch —
When the power is on the
fan motor will run and air will
be exhausted out the louvers
in the front of the machine.
The welding output and wire
feeder remain off until the
gun trigger is pressed.
2. Voltage Control — A 5-posi-
tion tap selector switch gives
full range adjustment of
power source output voltage.
Do not switch while welding.
3. Wire Speed Control —
Controls the wire feed speed
from 50 – 400 in/min (1.2 –
10.2 m/min). The control can
be preset on the dial to the
setting specified on the Pro-
MIG 175 Application Chart
located on the inside of the
wire feed section door.
OPERATION
®
-211-
ON
OFF
ARC VOLTS
WIRE SPEED
Pro-MIG 175
Refer to Figure B.1b.
4. Circuit Breaker – Protects machine from damage if
maximum output is exceeded. Button will extend
out when tripped (Manual reset).Refer to Figure B.1b
5. Gun Trigger - Activates welding output, wire feed,
and gas solenoid operation. Releasing the trigger
deactivates welding and simultaneously activates
the "burnback" function so that the welding wire
does not stick in the weld puddle.
1
FIGURE B.1a
FIGURE B.1b
B-2
3
2
Pro-MIG 175
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pro-mig 175

Table of Contents