TECHNICAL SPECIFICATIONS - PRECISION TIG 225 (K2533-1AND K2535-1,-2)
Standard Voltage
208/230/1/60
Output Current
Range
5-230 Amps (AC)
5-230 Amps (DC)
Process Duty Cycle**
GTAW
10% Duty Cycle
20% Duty Cycle
100% Duty Cycle
SMAW
10% Duty Cycle
20% Duty Cycle
100% Duty Cycle
**Chart gives max. rated Output Amps @% Duty Cycle (Based on a 10 minute cycle).
(Example; 180A@20% for AC/DC Stick and TIG)
* Inputs and ratings include a 20 amp rated load on the 115vac receptacle.
1
Output Limits allow for continuous max. rated load on 115vac auxiliary receptacle.
2
Wiring and protection based on the 2005 U.S. National Electric Code.
Use a Super Lag type fuse or circuit breaker with a delay in tripping action.
Models with NEMA 6-50P plug may be used with a 50 amp protected 6-50R receptacle, or with a maximum 70 amp protected 6-50R
receptacle if dedicated for the welder.

INSTALLATION

INPUT - SINGLE PHASE ONLY
Input Current at Rated Output
42A / 39A Effective
and 94A / 85A Maximum
OUTPUT RANGE
Maximum Open
Circuit Voltage
(STICK AND TIG)
AC OCV: 75
DC OCV: 66
RATED OUTPUT
Weld Current*
225A AC/DC
180A AC/DC
90A AC/DC (BAL.)
80A AC (AUTO-BAL.)
225A AC/DC
180A AC/DC
90A AC/DC
PRECISION TIG 225
Power Factor
Idle Current
0.62 Min.
3.0A/2.7A Max.
Type of Output
CC (Constant Current)
AC/DC
Weld Voltage (NEMA)
15.7 V AC/DC
15.2 V AC/DC
14.1 V AC/DC
14.0 V AC/DC
29.0 V AC/DC
27.2 V AC/DC
23.4 V AC/DC
A-1