F-27
Apply Positive Apply Negative
Test Probe to Test Probe to
Terminal
Terminal
1/8
12
12
1/8
9
4/5
4/5
9
1/8
9
9
1/8
12
4/5
4/5
12
NOTE: K ohm = ohm reading multiplied by 1000.
NOTE: Always make sure that Switch Boards are changed in matched pairs. Never mix an old style (different
part number) Switch Board with a newer style.
TROUBLESHOOTING & REPAIR
SWITCH BOARD TEST (CONT.)
TABLE F.2
SWITCH BOARD RESISTANCE CHECKS
Test Result
Conclusion Repair Action
Greater than OK
1K ohm
Less than
Shorted
100 ohms
Less than
OK
100 ohms
Greater than Open
1K ohm
Greater than OK
1K ohm
Less than
Shorted
100 ohms
Less than
OK
100 ohms
Greater than Open
1K ohm
Less than
OK
100 ohms
Greater than Open
1K ohm
Greater than OK
1K ohm
Less than
Shorted
100 ohms
Less than
OK
100 ohms
Greater than Open
1K ohm
Greater than OK
1K ohm
Less than
Shorted
100 ohms
V300-PRO
Next Procedure Notes
None
Continue
Replace both
Snubber Test
Switch Boards
None
Continue
Replace both
Snubber Test
Switch Boards
None
Continue
Replace both
Snubber Test
Switch Boards
None
Continue
Replace both
Snubber Test
Switch Boards
None
Continue
Replace both
Snubber Test
Switch Boards
None
Continue
Replace both
Snubber Test
Switch Boards
None
Continue
Replace both
Snubber Test
Switch Boards
None
Continue
Replace both
Snubber Test
Switch Boards
F-27